3-6 Riverstone Networks RS 3000 Switch Router Getting Started Guide
Installing the Hardware
Hardware Installation
Figure 3-6 Installing the line card into the chassis
Warning
The female and male connectors are not keyed, so it is possible to misalign
the connection. Ensure that all pins fit properly before applying power to the
RS 3000.
10.
Insert the six screws that hold the line card in place over the motherboard. Use the #2 Phillips-head
screwdriver to tighten the screws. If installing a line card that uses the extended EMI face plate,
insert and tighten the two additional screws that go through the center of the line card (see
11.
Replace the cover of the RS 3000, and secure it using the #2 Phillips-head screwdriver and the four
screws previously removed.
3.3.3
Installing GBIC Modules into GBIC MPLS Line Cards
GBIC line cards support two sockets for installing GBIC modules. One GBIC module can be installed into each
available socket.
shows an example of a GBIC module. The procedure following the figure describes how to install the
module into the GBIC line card.
2
1
1000BASE-SX
3
4
G2M-GSXA1-02
Tx
Rx
AN
Link
Tx
Rx
AN
Link
8
9
7
*
*
*
These two screws are
used only with extended
EMI face plate
RS 3000
CONSOLE
10/100 MGMT
OK
ERR
DIA
G
HBT
RST
2
1
1000BASE-SX
G2M-GSXA1-02
Tx
Rx
AN
Link
Tx
Rx
AN
Link
1
2