background image

11

Description of the step equipment

the Fun Pak "modena 660" is a complete counter-current and massage system 

which consists of::
a double stream counter-current system with air regulator, adjusta-

ble-power jets and handle. the jets can be manually switched to 10 

microjet massage jets and a master jet in the seating area, a floor gey-

ser in the foot area (optional) around the seating step and a water tor-

rent in the pool wall. Pump rating 2 x 1.5 kW - 230 V, switched from the 

control panel in the pool wall.

the masterjet massage jet and the 10 microjet massage jets can be opened 

and closed by turning them.

the jets of the counter-current system can be switched to the left or right onto 

the other attractions. in this case turn off the massage pumps before moving 

the jets.

the counter-current jets operate when the jets are in their middle position,
turn left hand jet to the left 

 

masterjet massage jet

turn left hand jet to the right 

 

Water torrent

turn right hand jet to the left 

 

microjet jets

turn right hand jet to the right 

 

floor geyser

3.5 

Fun Pak   "Modena 660“

 

Attractions and 
Functional overview

Na

ck

en

sc

hw

all

GS

A

GS

A

Ma

st

er

Je

t

Bod

eng

eysi

r

Mic

roJ

et

CC

S

JE

T

LEF

T

CC

S

JE

T

rig

ht

Na

ck

en

sc

hw

all

GS

A

GS

A

Ma

st

er

Je

t

Bod

eng

eysi

r

Mic

roJ

et

CC

S

JE

T

LEF

T

CC

S

JE

T

rig

ht

7

6

6

1

1

3

2

4

2

5

1  double stream CCs
2   microjet massage jets
3  masterjet massage jet
4  Water torrent

5  Floor geyser optional
6  Pn knob
7  air regulator

Summary of Contents for Fun Pak F4

Page 1: ...Technical Information SB 13 09 09 Operating instructions Fun Pak F 4 Counter current and massage equipment...

Page 2: ...n Pak Rimini Attractions and Functional overview page 9 3 4 Fun Pak Modena 370 Attractions and Functional overview page 10 3 5 Fun Pak Modena 660 Attractions and Functional overview page 11 3 6 Fun Pa...

Page 3: ...k as a standard feature is delivered completely pre assembled in the pool For this the RivieraPool foundation shaft is required for the corresponding steps If due to lack of space or building reasons...

Page 4: ...Our foundation shafts are fitted as standard with a shaft drain bonded connector d 50 Exception swimming pools with a shower tray or filtration equipment installed in the equipment shaft are additiona...

Page 5: ...aerator and humidity switch Set humidity switch to 65 The aerator must also run in winter when the swimming pool is switched off 4 Before doing the classing lay the shaft cover Leave sufficient space...

Page 6: ...nsert latching lightly into place To operate the jet inserts switch off the pump The power can be regulated by partially turning the jet insert Air can be mixed into the counter current swimming syste...

Page 7: ...nt system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their mid...

Page 8: ...her attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their middle position turn left hand jet to the left Masterjet mass...

Page 9: ...ets can be manually switched to 2 Microjet massage jets and a master jet in the seating area a floor geyser in the foot area optional around the seating step and a water torrent in the pool wall Pump...

Page 10: ...tem can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are in their middle po...

Page 11: ...counter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are...

Page 12: ...e counter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets a...

Page 13: ...unter current system can be switched to the left or right onto the other attractions In this case turn off the massage pumps before moving the jets The counter current jets operate when the jets are i...

Page 14: ...ockwise and withdrawing them from the jet element Loosen the Z bracket of the counter current equipment and remove the jets Plug the overwintering stoppers delivered with the system into the base of t...

Page 15: ...t opening of the jet bushing Attach the jet closers made from transparent PVC pipe and screw on the locking ring hand tighten While doing this ensure the diverter opening does not move in the process...

Page 16: ...www pools de One of the leading German manufacturers of prefabricated swimming pools swimming pool technology and whirlpools Member of BSW...

Reviews: