F. RCD Clear Mode:

   

Under the RCD reading mode or the hold mode, press and hold 

  to enter 

the RCD clear mode. Then 

  will be displayed. Press 

  and 

  to   

select and use 

  to confirm. The 

  twinkled means not to clear the data,   

and the 

  twinkled means to clear the data. When clearing the data,   

the 

  will twinkled, please waiting for the 

– below disappeared.   

 

G.Select Setting Mode: 

Under testing mode, press and hold 

  for more than two seconds, release 

  when 

 

appears, Use 

  and 

  to select options, press 

  to enter that mode. Press 

  again 

can exit. 
 

 

 

 
 

Select the setting mode to view the content as described below:                                         

Display content 

Description   

Hi.A    Lo.A 

Enter the alarm setting mode 

     

Enter the REF/SPAN setting mode 

 

Enter the DATE/TIME setting mode 

 

Enter the sampling rate setting mode 

       

 

Enter the temperature unit setting mode 

 

Exit the setting mode 

-8- 

-9- 

Summary of Contents for TX-600N

Page 1: ...descriptions 2 Display descriptions 3 Key descriptions 4 Instructions 6 RS 232 transfer protocol 11 Precautions 14 Please make sure to read the operation manual before using Please use the device corr...

Page 2: ...nctions Switchable 9 kinds of thermocouple type input Hi Lo Alarm T1 T2 Data hold Max Min Avg Functions USB RS 232 interface Perpetual calendar Data Logging Switchable AC DC power Battery sign and low...

Page 3: ...le switch key 10 USB Output port 4 Movement key 11 RS 232 Output connector 5 Movement key 12 T1 Probe input connector 6 Power switch 13 T2 Probe input connector 7 Model No and Serial No 2 This instrum...

Page 4: ...Celsius units Fahrenheit Hidden symbols Appeared when entering the setup mode or unusual condition Abnormal displays A When Area A shows please release all keys until the device return to normal stat...

Page 5: ...ime sampling rate temperature unit Under measurement mode press and hold more than two seconds when area A appears release the to enter the setting mode there are several selects in the setting mode p...

Page 6: ...firm The twinkled means not to clear the data and the twinkled means to clear the data It needs 7 to 10 seconds when processing this instruction Thermocouple switch mode Under testing mode press and h...

Page 7: ...alert data T1 T2 Real time Temperature display Area A T1 T2 Temp data Area B T1 Measuring data value Area C T2 Measuring data value Time and Date display Area A Year Area B Month day Area C Hour minut...

Page 8: ...d on the record mode Status Display contents Normal conditions Probe condition Probe type warning data condition Power indication T1 Real time Temperature display Area A T1 Measuring data value Area B...

Page 9: ...T1 HOLD display Hold the T1 temperature data T1 MAX display T1 maximum temperature data T1 MIN display T1 minimum temperature data T1 AVG display T1 average temperature data T2 HOLD display Hold the T...

Page 10: ...ng for the below disappeared G Select Setting Mode Under testing mode press and hold for more than two seconds release when appears Use and to select options press to enter that mode Press again can e...

Page 11: ...ange 200 00 0 00 3 DATE TIME setting mode This mode is for setting the date and time press to change the digit you want to change and press and to select the circulation figures Press and hold and can...

Page 12: ...ction Starting address Hi Starting address Lo No of Word Hi No of Word Lo CRC Lo CRC Hi 03H 03H 00H 00H 00H 01H 85H E8H Response Data Frame Ex response data 2 Byte 0x109D Slave address Functio n Byte...

Page 13: ...Data 4 Hi Data 4 Lo Data 5 Hi Data 5 Lo CRC Lo CRC Hi 08H FCH FFH 24H 00H 01H 38H 9FH Data 1 T1 Hi A 0x08FC 2300 Data 2 T1 Lo A 0xFF24 220 Data 3 T2 Hi A 0x08FC 2300 Data 4 T2 Lo A 0xFF24 220 Data 5...

Page 14: ...01 Bit 00 X X 1 0 X T2 Error 1 T1 Error 1 Power Power Meter is divided into 4 parts 11 100 75 10 74 50 01 49 25 00 24 0 Interpretation of data The data value read only observed in the real time testi...

Page 15: ...ter 3 If you want to get a more accurate measurement value keep a moment to let the temperature uniform and steady when measuring 4 When the instrument shows power shortages please replace the battery...

Page 16: ...MEMO...

Reviews: