Example
】
Set mode:
1. K Type thermocouple
2. Temperature unit=
℃
3. T1 no ERROR
4. T2 no ERROR
5. Power74~50%
MOD setting mode
0= K Type thermocouple, 1= J Type thermocouple, 2= E Type thermocouple,
3= T Type thermocouple, 4= B Type thermocouple, 5=R Type thermocouple,
6=N Type thermocouple, 7= S Type thermocouple, 8= C Type thermocouple.
Bit 07
Bit 06
Bit 05
Bit 04
Bit 03
Bit 02
Bit 01~ Bit
00
X
X
℉
=1
℃
=0
X
T2
Error=1
T1
Error=1
Power
☆
Power Meter is divided into 4 parts 11=100~75% 10=74~50%
01=49~25% 00=24~0%
Interpretation of data:
The data value read only observed in the real-time testing mode
The actual value of T1-real-time and T2-real-time is (Data-4000) / 10
The actual value of T1-Hi.A, T1-Lo.A, T2-Hi.A, and T2-Lo.A is read data value
Address/ Data name Comparison Table
Address
Data name
0000h
T1 Real-Time Data
0001h
T2 Real-Time Data
0002h
T1 Hi.A
0003h
T1 Lo.A
0004h
T2 Hi.A
0005h
T2 Lo.A
0006h
T1 T2 status (Type,
℃
/
℉
,Battery)
0007h
Record amount
-13-