ENGLISH
91
(*) Average temperature at nominal power. It is possible to obtain higher instantaneous exhaust gas tempe-
ratures. It is recommended to use always pipes with minimum specify T400.
TECHNICAL DATA
6
6.1
GENERAL TECHNICAL DATA
Weight
Nominal power
Efficiency
Emissions CO (13% O2)
Chimney vacuum
Exhaust gas temperature (*)
Exhaust gas flow
Combustible consumption
Max. combustible amount
Autonomy
Electric power
Tension
Frequency
344 kg
7,7 kW
87,1%
0,055%
12 Pa
195 °C
5,3 g/s
2,0 kg/h
3,0 kg
45 min
-
-
-
245 kg
7,7 kW
87,1%
0,055%
12 Pa
195 °C
5,3 g/s
2,0 kg/h
3,0 kg
45 min
-
-
-
294 kg
7,7 kW
87,1%
0,055%
12 Pa
195 °C
5,3 g/s
2,0 kg/h
3,0 kg
45 min
-
-
-
126 kg
7,7 kW
87,1%
0,055%
12 Pa
195 °C
5,3 g/s
2,0 kg/h
3,0 kg
45 min
-
-
-
Model
X Plus
X Basic
X Chef
X Vision
(**) For devices with nominal power lower than 8 kW it is not requested the test with reduced power (Vereinbarung Art. 15a B-VG
– 31.12.2012)
6.2
EMISSIONS ACCORDING TO 15A B-VG
Nominal power
Efficiency
Emissions CO
Emissions NOx
Dust Emissions
OGC Emissions
15a suitability (**)
7,7 kW
87,1 %
460 mg/MJ
67 mg/MJ
12,7 mg/MJ
41 mg/MJ
Yes
-
> 80 %
< 1100 mg/MJ
< 150 mg/MJ
< 35 mg/MJ
< 50 mg/MJ
-
Model
Serie X
15a B-VG