2.PROCEDURE FOR SETTING
IMCB10-E1
8
SL2 (Engineering unit selection)
z
For the input type of "Voltage/current input," even if the unit is set, it is ineffective.
z
Any digits other than the units digit are not used. As malfunction may result, do not
change any of these digits.
Factory set value : "0000"
Set value
Description
0
°
C
Engineering unit selection
1
°
F
0
0
0
Fixed
(3) SL3 (Action selection at the time of reset key operation)
z
When the reset action is taken by communication or contact input, all data items (peak
hold value and over time) are cleared.
z
Key operation is effective only when PV, peak hold value or over time is displayed.
z
Any digits other than the units and tens digits are not used. As malfunction may result, do
not change any of these digits.
Factory set value : "0000"
Set value
Description
0
0
Reset action taken and all data items cleared
*1
Selects the action on
0
1
Reset action taken and each data items cleared *2
each screen at the
1
0
Reset action taken and each data items cleared *3
of reset key
1
1
Reset action taken and each data items cleared *4
0
0
Fixed
All data items : Peak hold value and over time
*1 : Possible in any case where PV, peak hold value, or over time is displayed.
*2 : The reset action can be taken only when PV or over time is displayed. The peak hold value can be
cleared only when it is displayed.
*3 : The reset actin can be taken only when PV or peak hold value is displayed. Over time can be
cleared only when it is displayed.
*4 : The reset action can be taken only when PV is displayed. The peak hold value can be cleared only
when it is displayed. Over time can be cleared only when it is displayed.