3.
WIRING
IMR01N12-E7
17
Input 1 (pressure sensor input)
Input 1 can be used for the pressure sensor input. (Specify when ordering)
The strain gauge type of pressure sensor is only connectable.
The pressure sensor types must be specified when ordering. The relevant pressure sensors are as follows.
Our CZ-100P or CZ-200P
Resin pressure sensor (Strain gauge type)
*
other than RKC product
*
Rated output: 0.500 to 4.000 mV/V
Maximum supply voltage: More than 8 V DC
Directly connect the pressure sensor (without amplifier) connection cable to terminal numbers 14 to 18, 23 and
24. As for the sensor cable connection, refer to the instruction manual for Pressure sensor used.
* Terminal numbers 14 and 15 are not used.
Blue
Wiring example: Connection to our CZ-100P or CZ200P
Cable color
Black
Shield
Brown
Red
A C
B
D
Pin number
A
B
C
E
D
F
G
16
17
23
18
24
*
SHD Shield
EXC
Sensor
power
supply
EXC
Sensor
power
supply
SIG
Sensor signal input
SIG
Sensor signal input
15
14