256 • Description
EAGLE 2 Operator’s Manual
Appendix M: Tank Tester Model
The EAGLE 2 Tank Tester model is intended for checking tanks or vessels that may
contain residual hydrocarbon vapors or water or may have been purged of oxygen. It is
supplied as an LEL (catalytic) only unit or an LEL (catalytic)/oxygen unit. You can also
use this model as a standard EAGLE 2 gas monitor by connecting the standard hose and
probe and selection Normal Mode in the Inert Mode Selection Screen.
Description
The tank tester model has an additional socket on the front on the housing to
accommodate connection of the float probe assembly.
Figure 44: EAGLE 2 Tank Tester Version
This model includes the following non-standard components.
Table 35: Alarm Points for Tank Tester Configuration
Alarm 1
Alarm 2
LEL
10% LEL
1100 ppm
50% LEL
5500 ppm
Normal Mode
Oxygen
Oxy: 19.5% falling Oxy: 23.5% rising
Inert Mode Oxygen
Oxy: 5.0% rising
Oxy: 10.0% rising
Float
Probe
Socket
Quick Connect