28
M2A Transmitter Operator’s Manual
Wiring the M2A Transmitter
WARNING:
Always verify that the power source is OFF before making any wiring connections.
1. Remove the junction box cover.
2. Grasp the control PCB by its edges.
3. Gently pull until the control PCB is pulled away from the banana jacks. Take care not to pull too hard and
damage the cable which connects the control and terminal PCBs.
4. Let the control PCB hang by the cable. The terminal strips are now visible on the terminal PCB. The control
PCB may be left hanging while wiring is done. If desired, the control PCB may be disconnected from the
cable and set aside while wiring.
5. The detector leads are factory wired. Verify that the detector leads are wired to the detector terminal strip as
shown in the applicable figure below:
Catalytic LEL/Catalytic ppm/IR Combustible/IR CO
2
Detectors
The wiring for these types of detectors is the same. Red wire to terminal labeled LEL R, white wire to
terminal labeled LEL W, green wire to terminal labeled LEL G, black wire to terminal labeled LEL B.
Figure 21: Catalytic LEL and ppm Detector Wiring
Figure 22: IR Combustible/IR CO
2
Detector Wiring
Green
Black
White
Red
-
S
+
A
B
C
RS
4
8
5
PWR
/SI
G
R
W
G
B
LE
L
C
N
C
N
O
AL
A
R
M
1
C
N
C
N
O
AL
AR
M
2
C
NC
N
O
FA
IL
Green
Black
Red
White
-
S
+
A
B
C
RS
4
8
5
PW
R
/S
IG
R
W
G
B
LE
L
C
NC
N
O
AL
A
R
M
1
C
NC
NO
AL
A
R
M
2
C
NC
NO
FAI
L
www.
.com
information@itm.com
1.800.561.8187