34
Disassembly
Operating manual neoTower® Premium L / 03.2017
10. Disassembly
D
WARNING!
Hazard caused by failing to observe the disassembly
instructions.
This chapter contains important information regarding the
correct way to disassemble the system. Failing to observe
such information can lead to severe injuries.
A
Read this chapter carefully before disassembling the
system.
A
Follow the safety instructions.
A
Wait for the system to cool down before disassembling it.
A
Ensure that the cables are deenergised.
A
Ensure that the cables remain deenergised during the
work.
The disassembly must only be performed by trained
personnel.
Electrical work must only be performed by qualified,
skilled electricians.
D
“2.2.3 Trained personnel” (page 6).
A
Switch off the system.
“RMB/Control” operation manual.
A
Close all valves in the system.
A
Close all valves in the heating system.
A
Remove all cables from the control cabinet that are not
connected to the generation unit.
A
Remove the lines from the generation unit:
B
Buffer supply line
B
Buffer return line
B
Gas
B
Batteries
B
Condensate
B
Flue gas
B
Exhaust air
A
Remove the front cover from the generation unit.
A
Remove the lines from the calorific value heat exchanger
1
:
B
Buffer return line
B
Condensate
B
Flue gas
1
only with variant "neoTower® 50.0 Calorific value"