76
User's Guide HDSP System Multiface II
© RME
34. Technical Background
34.1 Lock and SyncCheck
Digital signals consist of a carrier and the data. If a digital signal is applied to an input, the re-
ceiver has to synchronize to the carrier clock in order to read the data correctly. To achieve
this, the receiver uses a PLL (Phase Locked Loop). As soon as the receiver meets the exact
frequency of the incoming signal, it is locked. This
Lock
state remains even with small changes
of the frequency, because the PLL tracks the receiver's frequency.
If an ADAT or SPDIF signal is applied to the Multiface, the corresponding input LED starts
flashing. The unit indicates LOCK, i. e. a valid input signal (in case the signal is also in sync,
the LED is constantly lit, see below).
Unfortunately, LOCK does not necessarily mean that the received signal is correct with respect
to the clock which processes the read out of the embedded data. Example [1]: The Multiface is
set to 44.1 kHz internally (clock mode Master), and a mixing desk with ADAT output is con-
nected to input ADAT1. The corresponding LED will show LOCK immediately, but usually the
mixing desk's sample rate is generated internally (also Master), and thus slightly higher or lower
than the Multiface's internal sample rate. Result: When reading out the data, there will fre-
quently be read errors that cause clicks and drop outs.
Also when using multiple inputs, a simple LOCK is not sufficient. The above described problem
can be solved elegantly by setting the Multiface from Master to AutoSync (its internal clock will
then be the clock delivered by the mixing desk). But in case another, un-synchronous device is
connected, there will again be a slight difference in the sample rate, and therefore clicks and
drop outs.
In order to display those problems optically at the device, the Multiface includes
SyncCheck
®
.
It checks all clocks used for
synchronicity
. If they are not synchronous to each other (i. e. abso-
lutely identical), the SYNC LED of the asynchronous input flashes. In case they are completely
synchronous, all LEDs are constantly lit. In example 1 it would have been obvious that the LED
ADAT 1 kept on flashing after connecting the mixing desk.
In practice, SyncCheck allows for a quick overview of the correct configuration of all digital
devices. So one of the most difficult and error-prone topics of the digital studio world finally
becomes easy to handle.
The same information is presented in the Multiface's Settings dialog. In the status display
SyncCheck
the state of all clocks is decoded and shown as simple text (No Lock, Lock, Sync).
Summary of Contents for Hammerfall Multiface II
Page 5: ...User s Guide HDSP System Multiface II RME 5 User s Guide Multiface II General...
Page 14: ...14 User s Guide HDSP System Multiface II RME...
Page 51: ...User s Guide HDSP System Multiface II RME 51...
Page 71: ...User s Guide HDSP System Multiface II RME 71 User s Guide Multiface II Technical Reference...
Page 80: ...80 User s Guide HDSP System Multiface II RME 35 Diagrams 35 1 Block Diagram Multiface II...