ANNEX
.........................................................................................................................................................................................................
...............................................................................................................................................................................................................
Manual EMC 500 · EN01 · 2008-02
54
Warnings
W
12-1
MethaneNo.Limit
Methane number outside limits
W
17-5
EMC S1 Offset
Sensor 1 hysteresis limit offset exceeded
W
18-5
EMC S2 Offset
Sensor 2 hysteresis limit offset exceeded
W
21-5
EMC TB Hyster.
Block temperature hysteresis limit exceeded
W
23-5
EMC CO2 Offset
Carbon dioxide hysteresis limit offset exceeded
W
35-1
Interface C1
Interface C1 out of order
W
35-2
Interface C2
Interface C2 out of order
W
35-3
Interface C3
Interface C3 out of order
W
35-4
Interface C4
Interface C4 out of order
W
35-5
Interface C5
Interface C5 out of order
W
72-5
Modb.Timeout C5
Timeout modbus C5
W
82-0
MB Function C2
Illegal function modbus C2
W
82-1
MB DataAddr. C2
Illegal data address modbus C2
W
82-2
MB DataValue C2
Illegal data value modbus C2
W
82-3
MB SlaveDev. C2
Slave device failure modbus C2
W
82-4
MB Acknowl. C2
Query understood, response pending, modbus C2
W
82-5
MB Busy C2
No response because device is busy, modbus C2
W
82-6
MB Neg.Ack. C2
Enquired function can not be started, modbus C2
W
82-7
MB Mem.Par. C2
Memory parity error modbus C2
W
83-0
MB Function C3
Illegal function modbus C3
W
83-1
MB DataAddr. C3
Illegal data address modbus C3
W
83-2
MB DataValue C3
Illegal data value modbus C3
W
83-3
MB SlaveDev. C3
Slave device failure modbus C3
W
83-4
MB Acknowl. C3
Query understood, response pending, modbus C3
W
83-5
MB Busy C3
No response because device is busy, modbus C3
W
83-6
MB Neg.Ack. C3
Enquired function can not be started, modbus C3
W
83-7
MB Mem.Par. C3
Memory parity error modbus C3
W
84-0
MB Function C4
Illegal function modbus C4
W
84-1
MB DataAddr. C4
Illegal data address modbus C4
W
84-2
MB DataValue C4
Illegal data value modbus C4
W
84-3
MB SlaveDev. C4
Slave device failure modbus C4
W
84-4
MB Acknowl. C4
Query understood, response pending, modbus C4
W
84-5
MB Busy C4
No response because device is busy, modbus C4
W
84-6
MB Neg.Ack. C4
Enquired function can not be started, modbus C4
W
84-7
MB Mem.Par. C4
Memory parity error modbus C4
W
85-0
MB Function C5
Illegal function modbus C5
W
85-1
MB DataAddr. C5
Illegal data address modbus C5
W
85-2
MB DataValue C5
Illegal data value modbus C5
W
85-3
MB SlaveDev. C5
Slave device failure modbus C5
W
85-4
MB Acknowl. C5
Query understood, response pending, modbus C5
W
85-5
MB Busy C5
No response because device is busy, modbus C5
W
85-6
MB Neg.Ack. C5
Enquired function can not be started, modbus C5
W
85-7
MB Mem.Par. C5
Memory parity error modbus C5
珠海司福斯特科技有限公司