Rhein-Nadel Automation GmbH

 

 

 

 

17  

VT-BA-ESK2002_EN-2020 / 06.05.2020 SJ 

5.5.6.  Code C006 Sensor linkage 

Objective:

 Linking of the two previously activated sensor inputs 

 

Select code 

 

 

 

 

Set code  

 

Code C006

 

 

 

 

 

 

 

You can activate only one of the eight sensor links at a time 
 

AND logic with blowing-off 
the exit tracks

 

 

 

 

I = active 
0 = not active 

 

AND logic with blowing-off 
the exit tracks
 

 

 

 

I = active 
0 = not active 

 

OR logic

 

 

 

 

I = active 
0 = not active 

 

Min/Max logic

 

 

 

 

I = active 
0 = not active 

 

AND / S2 logic

 

 

 

 

I = active 
0 = not active 

 

Level check with external

 

controller

 

 

 

 

I = active 
0 = not active 

 

Level check indicator light

 

 

 

 

I = active 
0 = not active 

 

Individual link

 

 

 

 

I = active 
0 = not active 

 

 

Use the following link to set priority of the channels. 

Channel 2 follows Channel 1

 

 

 

 

I = active 
0 = not active 

(both chan-

nels operate independently) 

 

 

Return

 

 

 

 

Save and return to 
main menu 

 

 

Brief description of individual links 

AND logic of the sensor inputs with blowing-off the exit track. 
Example: 

Application:  Twin-track feeders with accumulation checker. 

Solution:  Track 1 (sensor 1) full = Blow-off track 1 (relay K1) 

Track 2 still clear 
Track 2 (sensor 2) full = Blow-off track 2 (relay K2) 
Track 1 still clear 
Track 1 + Track 2 full = Bowl feeder (channel 1) Stop about 4 sec. later blowing air 
stop 

AND logic of the two sensor inputs without blowing-off the exit track. 
The bowl feeder (channel 1) stops when both sensors are operated. Orienting air can be switched off 
with delay (4 sec.) via relay K2. 

AND / S2 logic 
The bowl feeder (channel 1) stops when both sensors are operated. It starts when sensor 2 is cleared 
again. Orienting air can be switched off with delay via relay K2. 

OR logic of the two sensor inputs.

 

Bowl feeder (channel 1) stops when one of the two sensors is operated. Orienting air can be switched 
off with delay (4 sec.) via relay K2.  

Min/Max logic of the two sensor inputs.

 

The bowl feeder stops when both sensors are operated. The vibratory feeder (channel 1) will re-start 
only after both sensors are cleared again.  

Relay K1 operates on stopping of bowl feeder. Relay K2 operates 4 sec. later  
(stopping the blowing air) 

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

KANAL l
KANAL 2

CODE

Summary of Contents for ESK 2002

Page 1: ...Operating Instructions Controller for Vibratory Drive Systems ESK 2002...

Page 2: ...relays 11 5 Operation 12 5 1 General 12 5 2 Starting up the controller 13 5 3 Main menu Setpoint entry and display for channels 1 2 and 3 13 5 4 Description of individual codes for controller programm...

Page 3: ...4 35 EU and Electromagnetic Compatibility Directive 2014 30 EU We hereby declare that the product meets the following requirements Low Voltage Directive 2014 35 EC Electromagnetic Compatibility Direct...

Page 4: ...Only qualified professionals are allowed to work on or with the product IEC 60364 or CENELEC HD 384 define the qualification of these persons They are familiar with set up installation commissioning...

Page 5: ...ain even if all directives have been observed and protective measures taken Such residual hazards must be considered by the user in the risk assessment of his machine equipment Non observance may lead...

Page 6: ...type ESK 2002 16 for a total current of 16 A The unit offers the following characteristic features Three power outputs o Channel 1 bowl feeder max 10A variable o Channel 2 linear feeder max 4A variabl...

Page 7: ...or inputs 2 3 enabling inputs 24V DC 10 24VDC Sensor supply 24V DC max 60 mA per sensor input Sensor ON delay 0 60 sec separately adjustable Sensor OFF delay 0 60 sec separately adjustable Outputs 2 r...

Page 8: ...tion Attention Set the controller to minimum output before switching on for commissioning or start up after repairs or replacement of controllers vibratory drives Then watch proper operation while the...

Page 9: ...ive connector Where frequency controllers with selectable output frequency are used an EMC metal gland and a shielded cable are provided 4 3 Sensor inputs and sensor linkages The controller has two se...

Page 10: ...connect sensors of type NPN or PNP Proximity switch general NPN output Proximity switch general PNP output Sensor 2 Proximity switch general NPN output Sensor 1 Proximity switch general PNP output Con...

Page 11: ...hed on by its power switch closed The status output ACTIVE requires the same conditions for switching through as READY In addition the channel must be energized the transistor blocks in case of ACCUMU...

Page 12: ...ptocoupler outputs and external enabling inputs The controller display membrane keypad On Off Pressing this button switches off all connected devices The display shows OFF The controller remains ready...

Page 13: ...on of codes see under 4 4 Setpoint entry for channel 1 bowl feeder Entry in return to display mode for saving Setpoint entry for channel 2 Linear feeder or belt hopper with AC motor not available with...

Page 14: ...gnal direction Start delay Stop delay Setting the sensor input 2 This is the sub menu for activation of sensor input 2 In addition you can set the following functions Invert input signal direction Sta...

Page 15: ...and the vibratory or belt feeder function Select code Set code Code C002 Set vibrating amplitude Only in controller mode 0 100 Limit vibrating amplitude 50 100 External enabling I active 0 not active...

Page 16: ...ake any changes now through code C001 code C002 and code C012 Select code Set code Code C003 Setpoint vibrating amplitude 1 adjustable 0 input inhibited Return Save and return to main menu 5 5 5 Code...

Page 17: ...ack 2 still clear Track 2 sensor 2 full Blow off track 2 relay K2 Track 1 still clear Track 1 Track 2 full Bowl feeder channel 1 Stop about 4 sec later blowing air stop AND logic of the two sensor inp...

Page 18: ...active 0 not active Monitoring depending on Channel 2 I active 0 not active Time till alarm comes up 3 240 sec Switching off channel 1 and channel 2 I see below 0 see below Switch relay K1 I Alarm on...

Page 19: ...eturn Save and return to main menu Under menu item HA half wave you can check whether the operating mode 100 50 Hz is selected correctly 5 5 9 Code C200 Inhibiting all code entries Objective An accide...

Page 20: ...o default values or retrieving stored application specific settings Select code Set code Code C210 Default setting Application specific parameters Return Save and return to main menu FAC Select and ac...

Page 21: ...Rhein Nadel Automation GmbH 21 VT BA ESK2002_EN 2020 06 05 2020 SJ 6 Dimensioned drawing...

Page 22: ...feeder Capacitor motor Sensor 1 accu mulation Vibratory feeder 230V 50 60Hz supply connection M 2A Controller m c b Wire jumper not required for 50 60Hz required for 100 120Hz Wire jumper not require...

Page 23: ...ngenstr 96 CH 3360 Herzogenbuchsee Switzerland Tel 41 0 62 956 10 00 Fax 41 0 62 956 10 10 E Mail info handling systems ch www handling systems ch Manufacturing and Sales Pol Ind Famades c Energia 23...

Reviews: