INSTALLATION
Remove all the packaging materials and tape, as well as any protective plastic from
the machine. Clean off any glue residue left over from the protective plastic or tape
using methylated spirit.
Place the warmer on a firm, level surface in the required position. As a precaution, it
is recommended that all non-metal bench top surfaces be protected from heat with
some form of insulation. A piece of masonite, sheet metal, laminate or similar
material would be sufficient for this task.
Install the feet on the pie warmer, and adjust the feet individually to ensure the unit
is level.
Take a moment to inspect the unit to make sure that it is undamaged as a result of
any freight it may have been through. Familiarise yourself with the functioning of
the switches. Turn all of the switches on and off a couple of times to ensure you
are comfortable with their operation.
Before connecting the Pie Warmer to the power supply, ensure that the thermostat,
the light switch and the main On/Off switch are in the "OFF" position.
Plug the pie warmer into a standard, single phase, 10Amp power point.
National Standards exist outlining the positioning, spacing and ventilation
requirements when installing new appliances. These Standards should be
consulted and new equipment should be installed accordingly. In any situation
where specifications allow a distance of less than 100mm we would still
recommend that a well-ventilated air gap of not less than 100mm be maintained. If
the machine is near particularly heat-sensitive materials common sense should be
employed in determining sufficient distancing.
Always ensure the power cable is not in contact with hot parts of the Pie Warmer
when in use, and have any damaged power cord replaced immediately.