background image

TROUBLESHOOTING 

If the Urn is not heating then: 

 

Check that the machine is plugged into the 
power  point  correctly  and  the  power  is 
switched on.  

 

Check that the electrical circuit supplying the 
power  point  has  not  tripped.  This  could 
occur if: 

o

 

The circuit breaker has tripped. Too 
many  machine’s  connected  to  the 
circuit  will  exceed  the  current  limit. 
Remove  some  machines  from  the 
circuit and try again. 

o

 

The  Earth  Leakage  Device  has 
tripped.  It  is  normal  for  heating 
element  devices  to  leak  some 
current  through  the  insulation  to 
Earth.  If  multiple  machines  with 
heating  elements  are  connected  to 
the same circuit it could exceed the 
leakage  current  limit.  Remove  some 
machine  from  the  circuit  and  try 
again. 

 

Check  that  the  Urn  is  switched  to  the  ON 
position. The green pilot light indicates the 
urn is on and power is available. If the green 
light is not on check the power point is not 
faulty. 

 

In Variable mode check that the Thermostat 
is  turned  on  by  rotating  it  clockwise  to  an 
appropriate temperature setting. The amber 
pilot light indicates the urn is heating.  

 

If the unit has boiled dry, turn the machine 
off,  allow  to  cool,  tilt  backwards  and  press 
the reset button located on the base of the 
machine,  refill  the  machine  with  cold  water 
and turn it back on. See Operation. 

If the Urn boils continuously: 

 

For Variable Mode turn down the thermostat 
to  below  100°C  and  check  whether  the 
amber pilot light turns off.  

 

For Preset Mode check your altitude above 
sea  level.  The  Preset  thermostat  may  boil 
continuously  at  high  altitudes  above  800m. 
This  is  because  the  boiling  point  of  water 

decreases  as  altitude  increases.  It  is  not 
possible  to  recalibrate  the  internal 
thermostat  for  high  altitude  use.  Use 
Variable Mode only at high altitudes. 

 

SPARE PARTS 

Common 

EC0519 

Plug & Cord – 10A 

EC0385 

Pilot Light – Green  

EC0386 

Pilot Light – Amber  

EC0407 

On/Off Switch  

EC0457 

MODE Selection Switch 

MC1087 

Tap Top Assembly (Top Only) 

MC1088 

Tap Assembly Complete 

PC0589 

Tap Tank Seal 

PC0456 

Plastic Tank Washer 8.2OD, 

4.0ID 

PC0060 

Cord Clamp 10A 

PC0453 

Sight Glass Upper Mount 

TC0037 

Fixed Thermostat 95°C 

TC0049 

Boil Dry Cutout 

PC0593 

Push Rod – Boil Dry Cut-out 

TS0025 

Variable Thermostat & Knob 

PC0591 

Base Access Panel 

PC0594 

Dial / Knob Thermostat 

 

UDS10VP 

MS0458 

Sight Glass Assembly 10L 

PC0464 

Base 10L 

VS0253 

Side Handle Kit 10L 

VS0254 

Lid Assembly 10L 

TC0051 

Thermal Fuse Link 

 

UDB10VP 

Summary of Contents for UDS10VP

Page 1: ...Instruction Manual DOUBLE SKINNED HOT WATER URNS UDS10VP UDS20VP UDS30VP Version 3 UDB10VP UDB20VP UDB30VP Version 1...

Page 2: ...y damage to the appliance as a result of freight must be reported to the freight company and to the agent responsible for the despatch of the appliance within 24 hours of receipt No claims will be acc...

Page 3: ...regularly for any scale or other crusty deposits that may build up which are caused by minerals in the water The water should be checked from time to time to ensure no dust or small insects have found...

Page 4: ...ll occur on the lid as the steam vapour rises for this reason we have placed additional warnings on the lid The Urns have been designed to be as safe as possible but because these machines are frequen...

Page 5: ...iled dry turn the machine off allow to cool tilt backwards and press the reset button located on the base of the machine refill the machine with cold water and turn it back on See Operation If the Urn...