3
Beampath (standard Fresnel lens)
0
30000
24000
18000
12000
6000
0
(LUX)
1
0.8
0.6
0.2
0.2
0.4
0.6
0.8
Diameter (m)
1
2787
2230
1672
1115
557
0
(Foot-candles)
Distance=5m
8°
20 Distance (m)
6945
27780
3086
1736 LUX (center)
0.7
1.4
2.1
2.8 Diameter (m)
5
10
15
Be
am
o
pe
ni
ng
(
m
)
3
2
1
0
1
2
3
645
2580
287
161 Foot-candles (center)
0.4
Beam angle 8°- Min. zoom
Beam angle 50°- Max. Zoom
460
204
1840
115 LUX (center)
14
12
10
8
6
4
2
0
2
4
6
8
10
12
14
43
171
19
10 Foot-candles (center)
Be
am
o
pe
ni
ng
(
m
)
20 Distance (m)
4.7
9.3
14
18.6 Diameter (m)
5
10
15
50
°
0
2000
1500
1000
500
0
(LUX)
4
3.2
2.4
0.8
0.8
1.6
2.4
Diameter (m)
Distance=5m
1.6
3.2
4
186
139
93
46
0
(Foot-candles)
13. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light output very quickly. The cooling fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
The dichroic colour filters should be cleaned monthly.
There are no serviceable parts inside the device except for the lamp and the fuse.
Please refer to the instructions under "Fitting/Exchanging the lamp".
Maintenance and service operations are only to be carried out by authorized distributors.
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of same
type and rating.
Before replacing the fuse, unplug mains lead.