13. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front Fresnel lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light output very quickly. Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-
-cleaner. The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour filters, CMY flags and an internal lens should be cleaned monthly.
Maintenance and service operations are only to be carried out by authorized distributors.
Important! Check the air filters periodically and clean before they become
clogged!
Clean the air filters with a vacuum cleaner, compressed air or you can wash them and put back dry.
Replacing the air filters in the fixture head.
1)Disconect the fixture from power.
2)Remove both top and bottom cover of the head (by loosening the 4 quarter-turn fasteners on
each cover).
3)Remove the air filters (they are fixed with Velcro fastener) from grids.
4)Clean or replace the air filters.
5)Place the filters on the grid and put head cover back.
6)Reset the elapsed time counter in menu Fixture information (Fixture Information--->Air Filters--->
Elapsed Time.
Replacing the air filter in the fixture base.
1)Disconect the fixture from power
2)Remove side fans cover by loosening the 4 quarter-turn fasteners.
grid