background image

14

10. Appendix- Changing the power supply settings

Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the moving head.The factory settings are printed
next to the power cord.

If you want to change the power supply settings,follow the instructions:

UE version:
1.Disconnect the fixture from AC power.
2.Remove the control board cover by loosening the 4 screws.
3.Move the  wire  1  on the transformer connection block to the position according to the desired voltage.

  Example:

4.Put the cover back before applying AC power.

Transformer

Ballast

Control board cover

Front cover

Fastening screws

Fastening screws

Summary of Contents for DJ SCAN 150 XT

Page 1: ......

Page 2: ...mp 6 4 2 Rigging the fixture 7 4 3 Connection to the mains 8 4 4 DMX 512 connection connection between fixtures 8 5 DMX PROTOCOL 9 6 Addressing 10 7 Control Board 10 7 1 Main functions 10 7 2 Special functions calibration 11 8 Technical specifications 11 9 Maintenance and cleaning 13 10 Appendix Changing the power supply settings 14 DJ SCAN 150 XT ...

Page 3: ...with other cables Handle the power cord and all connections with the mains with particular caution Always plug in the power plug least The power plug has to be accessable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before c...

Page 4: ...ate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature ta 45 C must never be exceeded Otherwise the lamp is switched off and the fixture is out...

Page 5: ...ion of the device Front panel 1 Fuseholder 2 Powercord 3 DMX input 4 DMX output Control board 1 Menu button 2 Up Down buttons 3 Display 1 Fixation screw for bracket 2 Bracket 3 Fastening screws 4 Objective 5 Mirror ...

Page 6: ...e socket Insert the lamp to the socket Do not install a lamp with a higher wattage A lamp like this generates temperatures the device is not designed for Damages caused by non observance are not subject to warranty Please follow the lamp manufacturer s notes Do not touch the glass bulb bare hands during the installation Make sure that the lamp is installed tightly into the lampholder system Reinse...

Page 7: ...four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The projector should be installed outside areas where persons may walk by or be seated Important Overhead rigging requires extensive experience including but not limited to calculating working load limits installation mate...

Page 8: ...nnectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug If you are using standard controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you ...

Page 9: ... step 120 127 Blue purple step 128 190 Forwards rainbow effect from fast to slow proportional 191 192 No rotation step 193 255 Backwards rainbow effect from slow to fast proportional 4 Shutter Strobe Gobos 0 5 Closed step 6 63 Open step 64 127 Strobe effect from slow to fast max 8FPS proportional 128 132 Closed step 133 135 Reset of the fixture step 136 143 Open step 144 151 Closed step 152 159 Go...

Page 10: ... not received these data s at the DMX input the display will start to flash slowly 001 with actually set address This situation can be occurred if there is not connected the 3 PIN XLR plug cable with DMX signal from controller in the input of the DJ SCAN 150 XT the controller is switch Off or is failed the cable or connector is failed or the signal wires are swap in the input connector Note It s n...

Page 11: ...on value of the colour wheel Use Up and Down keys to adjust a new calibration value from range C00 C15 the wheel moves in microsteps so you can easilly center current colour Press Menu on the display will appear message G08 meaning the calibration value of the gobo wheel Use Up and Down keys to adjust a new calibration value from range G00 G15 the wheel also moves in microsteps so you can easilly ...

Page 12: ...ffect calibration reset of the unit and built in test sequence running Digital serial input DMX 512 4 control channels Channel 1 Horizontal mirror movement Pan Channel 2 Vertical mirror movement Tilt Channel 3 Colour wheel Channel 4 Gobos shutter strobe Housing Easy access to lamp and main components thanks to large opening cover and the projector s modular construction Temperatures Maximum ambien...

Page 13: ...ing will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life Please use a moist lint free cloth Never use alcohol or solvents The front mirror objective lens will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleaned monthly The gobos may be cleaned...

Page 14: ... printed next to the power cord If you want to change the power supply settings follow the instructions UE version 1 Disconnect the fixture from AC power 2 Remove the control board cover by loosening the 4 screws 3 Move the wire 1 on the transformer connection block to the position according to the desired voltage Example 4 Put the cover back before applying AC power Transformer Ballast Control bo...

Page 15: ... 4 screws 3 Move the wire 1 on the transformer connection block to the position according to the desired voltage 4 Move the wire 2 on the ballast connection block to the position according to the desired frequency voltage Example 4 Put the cover back before applying AC power Transformer Ballast ...

Reviews: