3. Unpacking & Inspection

Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact. 

Before beginning initial setup of your ROBE Fog Machine, make sure that there is no evident damage caused 

by transportation.  In the event that the unit's housing or cable is damaged, do not plug it in and do not attempt 

to use it until after contacting your ROBE distributor for assistance.

4. Setup

Remove all packing materials from shipping box. Check that all foam and plastic padding is removed, espe-

cially in the nozzle area.

Place fog machine on a flat surface and remove fog liquid tank cap.

Fill with only an original liquid recommended by ROBE distributor. Other liquids may cause spitting and serious 

clogging problem and could result in the production of an unhealthful fog. The use of other liquids voids the 

warranty of the Fog 1500 FT. When filled, place cap back on liquid tank.

Firmly attach the control module cable to the connector inside the rear chamber of the machine.  

WARNING:

Use of any liquid other than  original liquid recommended by ROBE distributor or modification or attempted to 

unauthorized repair of the Fog 1500 FT will immediately invalidate the warranty.

5. Operation

The plug is positioned that the plug is accessible when used machine.

Plug power cord into a grounded electrical outlet.  Turn power switch on rear of unit to "ON" position. Warm-up 

is complete when the display on control module shows "Ready to Fog."

To emit fog, press the appropriate button on the control module for the desired length of time.

The control unit's display will cycle "Warming up" and "Ready to Fog" as the machine re-heats to the proper 

operating temperature.

When the liquid is running low, the LED inside the tank chamber starts blinking for two minutes and then stop 

operation to protect the pump from running dry..

Always monitor liquid level to prevent interrupted operation.

For further information on operating your Fog 1500 FT, see the section titled, "Control Module Operation" on 

page 6.

Caution

: "Visibility during operation is reduced"

If your model includes a mounting bracket designed for overhead installation, it may be installed at floor level 

or suspended overhead. If the unit is to be mounted using the bracket, it is important that the fog does not 

shoot directly at any one's face. Whatever installation method you choose, do not allow the unit to have more 

than a 15 degree angle of inclination.

Important!  

Always monitor tank liquid level as you are fogging.

Running a fog machine with no liquid can permanently damage the unit. 

If you experience low output, pump noise or no output at all, unplug immediately. Check liquid level, the exter-

nal fuse, control module connection, and power from the wall.  If all of the above appears to be O.K., plug the 

unit in again. If fog does not come out after holding the control module button down for 30 seconds, check the 

hose attached to the tank to make sure there is liquid going through the hose. If you are unable to determine 

the cause of the problem, do not simply continue pushing the control module button, as this may damage the 

unit. Return the machine to your ROBE distributor immediately.

Summary of Contents for Fog 1500FT

Page 1: ...USER MANUAL Version 1 0 ROBE Show Lighting s r o Czech Republic www robe cz ...

Page 2: ......

Page 3: ...tion 4 2 Cautions 4 3 Unpacking Inspection 5 4 Setup 5 5 Operation 5 5 1 Control Module Operation 6 5 Technical specifications 7 6 Performance Notes 7 7 Configuration the pump power for local AC power 7 8 Maintenance and cleaning 7 ...

Page 4: ...e directly at people Fog machine output area is very hot Avoid coming within 60 cm of the output nozzle during operation Locate the fog machine in a well ventilated area Never cover the unit s vents In order to guarantee adequate ventilation allow a free air space of at least 20 cm around the sides and top of the unit Never aim the output nozzle at open flames If the supply cord is damaged it must...

Page 5: ...ss the appropriate button on the control module for the desired length of time The control unit s display will cycle Warming up and Ready to Fog as the machine re heats to the proper operating temperature When the liquid is running low the LED inside the tank chamber starts blinking for two minutes and then stop operation to protect the pump from running dry Always monitor liquid level to prevent ...

Page 6: ...onfirm setting 3 Press ESC Timer key to exit current menu level and move to an upper previous level 4 Press the Timer key to activate the timer function The display shows the adjusted interval and the device counts the seconds down to 0 After that the fog emission is triggered at the volume adjusted under Timer Option The duration depends on the settings adjusted under Duration If you wish to deac...

Page 7: ... turned off 7 Configuration the pump power for local AC power The device pump is factory configured for 230V 50Hz If your AC power is different the pump power can be configured for the local voltage using the follow procedure 1 Press the Function Key and turn on the machine at the same time 2 Continue to press the Function Key for about 5 sec 3 ROBE logo will appear on the display and after that m...

Page 8: ...use Clean with a dry cloth only Store dry Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges Replacing the fuse Before replacing the fuse unplug mains lead Replace the fuse by a fuse of the same type and rating Note The warranty does not extend to any parts of the Fog 1500 FT that have been subject to misuse or accident Neither does the warranty cover ...

Page 9: ...9 ...

Reviews: