6
7
In general, Fog 1500 FT conform to the following performance specifications:
1. Average Operating temperature = 2500°C
2. Fog 1500 FT can maintain maximum output for 60 seconds or more.
5. Technical specifications
Power supply:
Power consumption: .......... 1430 VA
Voltage: ............................. AC 230 V, 50 Hz
Fuse: ................................. T7 A@230V
DMX:
3 pin and 5 pin XLR sockets
Tank capacity:
6 Liter
Output:
20.000 Cu.ft/Min.
Output pressure:
49 kPa
Heat Up time:
11 min.
Liquid cons. rate:
13 Min/Liter (100% output)
Dimensions:
645 x 240 x 190 mm
Weight:
15,5 kg
6. Performance Notes
Set the volume to „Nonstop Burst“ to have continuous output. When in such setting, the thermostat keep
detecting heater temperature and adjust output automatically.
Fog 1500 FT has a recycling period after long bursts when the machine will shut itself down for a short period
in order to heat up again. During this time, no fog can be produced.
Fog 1500 FT may sputter small amounts of fog occasionally during operation and for a minute or so after
being turned off.
7.Configuration the pump power for local AC power.
The device pump is factory configured for 230V/50Hz.If your AC power is different,the pump power can be
configured for the local voltage using the follow procedure:
1. Press the Function Key and turn on the machine at the same time.
2. Continue to press the Function Key for about 5 sec.
3. „ROBE“ logo will appear on the display and after that message „Voltage change“
4. press the Enter Key
5. The current voltage will appear on the display.Use Up and Down Keys to choose the one you need:
110V 50-60Hz
120V 50-60Hz
220V 50-60Hz
230V 50-60Hz
240V 50Hz
6. Presss Enter Key after chosen the voltage
7. The main screen will appear on the display
8. Maintenance and cleaning
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and
the fog machine liquid tank immediately after filling.
After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80%
distilled water and 20% white vinegar through the system to prevent the accumulation of particulate matter in
the heating element. The recommended cleaning regimen is as follows: