6
SENSOR_VALUE
*
DISPLAY_INVERT
*
*
DISPLAY_LEVEL
*
*
PAN_INVERT
*
*
TILT_INVERT
*
*
DEVICE_RESET
*
DMX_PERSONALITY
*
*
DMX_PERSONALITY_DESCRIPTION
*
STATUS_MESSAGES
*
STATUS_ID_DESCRIPTION
*
LAMP_STATE
*
*
LAMP_ON_MODE
1
*
*
DEVICE_HOURS
2
*
LAMP_HOURS
2
*
LAMP_STRIKES
2
*
1
...Another options for this command (only for Robe´s fixtures):
value PARAMETER_DATA=0x84 - lamp OFF by DMX value on DMX channel
value PARAMETER_DATA=0x88 - lamp OFF if DMX is not present
2
...Commands relative resetable values
9. Wireless DMX operation
The wireless version of the Robin 600E Wash is equipped with the Lumen Radio CRMX module and antenna
for receiving DMX signal. CRMX module operates on the .4 GHz band.
To link the fixture with DMX transmitter.
The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter .
After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item “Wireless State“ (Information
-->Wireless State)
To unlink the fixture from DMX transmitter.
The fixture can be unlinked from receiver via the menu item “ Unlink Wireless Adapter“ (Personality--> Unlink
Wireless Adapter.-->).
10. Error and information messages
Occurred errors during fixture operation are signalled by the yellow warning icon at the bottom line of the
screen:
Touch the warning icon or press the [ESCAPE] button to display error messages.
List of error and information messages:
Active Lamp Timer
This message appears if you try to switch on the lamp within 5 minutes after having switched it off. The fixture will
store the attempt to ignite the lamp and automatically ignites the lamp when the 5 minutes period will expire.
Lamp Error
If the ignition of the lamp is 4 times unsuccessful (the “Active Lamp Timer” message appeared 3 times before),
the display shows “Lamp Error”, meaning that the lamp could be damaged or even missed or there could be a
failure on the igniter or ballast.
Overheated
This message informs that the fixture had been overheated and the lamp was switched off by means of the