7
head temperature sensor.
Lamp is too hot
The message will appear on the display if the lamp doesn’t ignite within 5 seconds.
Temper.Sensor Error
The message informs you that the communication betwen the head temperature sensor and the main proces-
sor failed and the lamp has been switched off.
Tilt Error 1
(Tilt Error 2)
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Pan Error 1
(Pan Error 2)
This message will appear after the reset of the fixture if the yoke´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The yoke is not
located in the default position after the reset of the fixture.
Colour Wheel Error 1(Colour Wheel Error 2
)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default posi-
tion.
Cyan Lamella Error 1 (Cyan Error 2 )
The messages will appear after the reset of the cyan flag if the flag is not located in the default position.
Magenta Lamella Error 1 (Magenta Error 2 )
The messages will appear after the reset of the magenta flags if the flag is not located in the default position.
Yellow Lamella Error 1 (Yellow Error 2 )
The messages will appear after the reset of the yellow flags if the flag is not located in the default position.
CTO Lamella Error 1 (CTO Lamella Error 2)
The messages will appear after the reset of the CTO flag if the flag is not located in the default position.
Strobe 1 Error 1 (Strobe 1 Error 2 )
The messages will appear after the reset of the dimmer/strobe module if the strobe lamella is not located in
the default position.
Strobe 2 Error 1 (Strobe 2 Error 2 )
The messages will appear after the reset of the dimmer/strobe module if the strobe lamella is not located in
the default position.
Zoom Error 1 (Zoom Error 2 )
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Clean Air Filters
The message informs that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean air
filters and reset this counter.