4.6 Installing handle for the Follow Spot Mode
Before installation of handle (handles) , switch the fixture to the Follow Spot Mode (Personality--> Follow Spot
Mode). You can install one or two handles in different positions as needed. See picture below. Before switching
the Follow Spot Mode off, remove handle (handles) from the fixture.
4.7 Replacing light frost
Install light frost module with the device switched off only.
Unplug from mains before!
To replace the light frost module.
1. Disconnect the fixture from mains and allow it to cool for 10 minutes.
2. Move the head to the position that signs on the lamp cover (1) lead down (turned by 180°)
3. Remove plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
4.
Remove the fan assembly (2) by unscrewing two screws (3) on both sides of the fan assembly.