36
Tilt Error 1 (Tilt Error 2)
This message will appear after the reset of the fixture if the head´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head is not
located in the default position after the reset.
Tilt Error 3
This message signalizes error of the tilt feedback. Check connection of the tilt sensor.
Pan Error 1 (Pan Error 2)
This message will appear after the reset of the fixture if the yoke´s magnetic-indexing circuit malfunctions (sen
-
sor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The yoke is not
located in the default position after the reset of the fixture.
Pan Error 3
This message signalizes error of the pan feedback. Check connection of the pan sensor.
Pan/Tilt EMS Call Error
If the message appears, run Pan/Tilt EMS calibration (tab Service --> Calibration --> Calibrate Pan/Tilt EMS)
Colour Wheel 1 Error 1(Colour Wheel 1 Error 2
)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default posi-
tion.
Colour Wheel 2 Error 1(Colour Wheel 2 Error 2
)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default posi-
tion.
Cyan Lamella Error 1 (Cyan Error 2 )
The messages will appear after the reset of the cyan flag if the flag is not located in the default position.
Magenta Lamella Error 1 (Magenta Error 2 )
The messages will appear after the reset of the magenta flags if the flag is not located in the default position.
Yellow Lamella Error 1 (Yellow Error 2 )
The messages will appear after the reset of the yellow flags if the flag is not located in the default position.
CTO Lamella Error 1 (CTO Lamella Error 2)
The messages will appear after the reset of the CTO flag if the flag is not located in the default position.
Prism 1 Error 1 (Prism 1 Error 2 )
The messages will appear after the reset of the 6-facet linear prism if this prism is not located in the default
position.
Prism 1 Rot. Error 1 (Prism 1 Rot. Error 2 )
The messages will appear after the reset of the 6-facet linear prism if the prism rotation is not in the default
position.
Prism 2 Error 1 (Prism 2 Error 2 )
The messages will appear after the reset of the 6-facet axial prism if this prism is not located in the default
position.
Zoom Error 1 (Zoom Error 2 )
The messages will appear after the reset of the zoom module if the zoom lens is not located in the default
position.
Focus 1 Error 1 (Focus 1 Error 2 )
The messages will appear after the reset of the focus module if the focus module is not located in the default
position.
Focus 2 Error 1 (Focus 2 Error 2 )
The messages will appear after the reset of the focus module if the focus module is not located in the default
position.