36
Fr. Shutters Rot. Error 1 (Fr. Shutters Rot. Error 2 )
The messages will appear after the reset of the framing shutters module if this module is not located in the
default position.
Fr. Shutter 1 Error 1 (Fr. Shutter 1 Error 2 )
The messages will appear after the reset of the framing shutters module if the frame 1 is not located in the
default position.
Fr. Shutter 2 Error 1 (Fr. Shutter 2 Error 2 )
The messages will appear after the reset of the framing shutters module if the frame 2 is not located in the
default position.
Fr. Shutter 3 Error 1 (Fr. Shutter 3 Error 2 )
The messages will appear after the reset of the framing shutters module if the frame 3 is not located in the
default position.
Fr. Shutter 4 Error 1 (Fr. Shutter 4 Error 2 )
The messages will appear after the reset of the framing shutters module if the frame 4 is not located in the
default position.
EEprom Error
Hardware error of the EEprom.
Recharge The battery
The battery on the display board needs to be charged. Let the fixture on for cca 6 hrs.
Battery Faulty. Replace it.
The battery on the display board is exhausted and should be replaced immediately.
Pan/Tilt EMS Cal. Error
The EMS system is not calibrated.
Pan/Tilt EMS Error
Control electronics cannot communicate with the EMS system.
Internal Error 1
Communication error between PCBs (error or noise was detected on communication wires)
Internal Error 2
Communication error (some PCB has failed or is disconnected (this PCB will show as N/A in menu --> Infor
-
mation --> Software versions) or error/noise was detected on communication wires)
Clean Air Filters
The message informs you that the item "Elapsed Time" in the "Fixture Information" menu is at 0 value. Clean
air filters and reset this counter.
Blue 1 Short Error/ Blue 2 Short Error/ Blue 3 Short Error/ Blue 4 Short Error
Some blue LEDs in the light source have short circuit or are disconnected.
Green 1 Short Error/ Green 2 Short Error
Some green LEDs in the light source have short circuit or are disconnected.
Light Green 1 Short Error/ Light Green 2 Short Error/ Light Green 3 Short Error/ Light Green
4 Short Error
Some light green LEDs in the light source have short circuit or are disconnected.
Amber 1 Short Error/ Amber 2 Short Error/ Amber 3 Short Error/ Amber 4 Short Error
Some amber LEDs in the light source have short circuit or are disconnected.
Red 1 Short Error/ Red 2 Short Error/ Red 3 Short Error/ Red 4 Short Error