4. Installation
Fixtures must be installed by a qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
ns.
4.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin T1 Profile is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 V
olts.
Power cable is enclosed to the fixture.If you need to install a power plug on the power cable to allow connection
to power outlets, install a grounding-type (earthed) plug, following the plug manufacturer’s instructions. If you
have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
This device falls under class one and must be earthed (grounded).
To apply power, first check that the head pan and tilt locks are released.
4.2 Replacing the frost
Unplug the fixture from mains before installing the frost module!
To replace the frost module.
1. Disconnect the fixture from mains and allow it to cool for 10 minutes.
2. Remove plastic cover of the head by loosening the 2 quarter-turn fasteners on the cover to get access to
the frost module (1).
3
. The holder (2) of the frost foil is fastened to the frost holder (3) by means of the four magnets (4). Grip the
holder (2) and carefully tilt it out to break a force of magnets (4) on the frost holder (3).
4
. Place a new frost module into the frost holder (3). Check, that both slots (6) snapped correctly into two
protrusions (5) in the holder (3).
5. P
lace the plastic cover back on the fixture before applying power.