4. Level the frame and tighten to the wall as shown on page 8 and here in Fig. 4. The left keyhole is elongated to allow for up and down
adjustment.
5. Install the four Structural Screws (203-1256) into the four top frame holes (Fig. 5). A T-30 Torx Bit is provided. If the wall is bowed,
shim where required.
6. If required, shim the bottom at the frame/side intersection (Fig. 6).
7. Install two #10 x 2" (SS674) through the narrow slot of the keyhole on the flange (Fig. 7).
FRAME INSTALLATION
4
6
5
7
[203-1256]
5/16" x 2 1/2"
4-Structural Bolt
4-Boulon
4-Perno estructural
SS674
#10 - 2"