12
© 2020 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
Installation instructions
Part no. 209-1289 rev. 03/10/20
Profiles Framed Cabinet
SURFACE MOUNTING
3. Center Z-mounting bar at cabinet location. Make sure Z-mounting bar is at least 1” (25 mm) above fixtures.
5b
3
4
5a
5/16"
(8 mm)
203-1349
SS674
1" (25.4 mm)
Minimum
Z Mounting Bar
1" x 3"
#10 x 2"
(51 mm)
[SS674]
7/32"
(5.5 mm)
1" (25.4 mm)
Minimum
Drill Here
4. Locate and drill three 7/32” (5.5 mm) holes through the indent line on the mounting bar. Be sure the mounting bar is level. Make sure
Z mounting bar is centered.
5a. Use three #10 X 2” (SS674) screws provided to attach the Z-mounting bar mounting strip to the wall.
5b. If no furring strip or stud is available, use the supplied plastic anchors, making sure that each cabinet is supported by at least 3
anchors. Drill a 5/16” (8 mm) hole for wall anchors and insert the wall anchor into hole until the anchor flange is flush with the wall.
5c. Use the #10 screw and tighten screw until there is a strong resistance. DO NOT OVER TIGHTEN.