6 Troubleshooting
SYMPTOMS
POSSIBLE REASONS
SOLUTIONS
Light does not switch on
No lamp installed
Put a lamp
The lamp is installed but
defective
Control / replace the lamp
The lamp compartment is not
properly tightened
Tighten the two knobs to activate the micro-
switch contactors
Defective micro-switches
Change the micro-switch(es)
Electrical connection
Check the connections
The beam is not uniform
The lamp is not aligned
Replace the lamp
Peak/Flat adjustment
Turn the knob to reach the expected
adjustment
Non compatible lamp
See the list of compatible lamps
The size of the beam
between two fixtures is not
the same
Zoom configurations are not
identical
See chapters referring to possible
configuration changes (4.2.1 et 3.3.4)
The lamp does not switch
on immediately
Cold strike lamp
Wait 20 minutes before powering up again