background image

TIBO - 525 - Version V1

HID FRESNEL LENS - 250 W /

 

PROJECTEUR FRESNEL A DECHARGE 250 W

SINGLE LENS LUMINAIRE / 
PROJECTEUR FRESNEL

VALIDATION : 09/04/15

DN41044300 

Robert Juliat S.A.S.  32, rue de Beaumont,  F 60530 Fresnoy-en-Thelle  -  phone : +33 (0)3 44 26 51 89 - fax : +33 (0)3 44 26 90 79 - info@robertjuliat.fr

www.robertjuliat.com

TIBO

M

anual / 

Ma

n

uel

Reference

Standard

Référence

Standard

250 W HID (G12)

525

Summary of Contents for TIBO-525

Page 1: ...LUMINAIRE PROJECTEUR FRESNEL VALIDATION 09 04 15 DN41044300 Robert Juliat S A S 32 rue de Beaumont F 60530 Fresnoy en Thelle phone 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr www r...

Page 2: ...al and the lighting unit 4 3 1 3 Instructions for use 4 3 1 4 Hanging 5 3 1 5 Safety cable 5 3 2 Electrical data 6 3 2 1 Lamp 6 3 2 2 Power Supply 7 3 3 Accessories 8 3 3 1 Front filter holder and bar...

Page 3: ...nt of the fixture 12 The combined weight of both the fixture and the accessories must be considered when choosing the load bearing capability of safety cable or bond 13 Do not open lighting fixture wh...

Page 4: ...andle 2 Hanging yoke 3 Tilt locking handle 4 Beam angle adjustment 5 Safety cable attachment point 6 Unit rotation locking button 7 Tilt index 8 Front slot locking system 9 Front slot for accessory an...

Page 5: ...on 1 PCP1716A 16A blue 2P E 6h IEC60309 P17 power connector 2 CF100 4 leaves on a barndoor 135x135mm without safety cable 3 872 Doughty Twenty clamp with M10 screw nut for 48 to 51mm pipes SWL 20Kg T...

Page 6: ...up 3 1 Mechanics 3 1 1 Operating positions 3 1 2 Minimum distance between a flammable material and the lighting unit 3 1 3 Instructions for use Minimum 40 C 104 F 5 C 41 F IP20 Indoor use only Maximum...

Page 7: ...an additional hanging accessory such as safety bond or cable of suitable length Safety cables or bonds must be securely attached to the back of the fixture and be as short as possible or rolled up as...

Page 8: ...e hot The fixture must be cold prior to any intervention Never touch or handle the lamp bulb with bare hands 1 Unscrew the 2 screws A of the lamp compartment 2 Pull the lamp compartment out 3 Place th...

Page 9: ...lamp 1 2 A 3 2 2 Power Supply Class 1 equipment Mandatory earth grounding Can be connected to an external electronic dimmer Power cable Cable Connectors Cable reference Length Cabling 1 Standard Vers...

Page 10: ...EN EN 8 3 3 Accessories 3 3 1 Front filter holder and barndoors Step 1 3 3 1 Front filter holder 3 3 2 Barndoors Step 2...

Page 11: ...EN EN 9 4 Operation 4 1 Beam size adjustment 4 1 1 Range Minimum angle Maximum angle Beam angle 45 33 Field angle 58 82 Beam angle 50 Field angle 3 4 1 2 Control...

Page 12: ...EN EN 10 4 2 Orientation 4 2 1 Range Function Range PAN 0 360 TILT TU 0 67 TD 0 90 4 2 2 Control PAN TILT...

Page 13: ...EN 1 leaf 2 leaves 3 leaves 4 leaves Open EN 11 Type Standard coloured gel filter Dimensions Installation See 3 3 1 Values are in mm 4 3 Colour Fixed colour 4 4 Beam shaping Barndoors 4 4 1 Range...

Page 14: ...oose contacts No missing parts Tighten mechanical assemblies screws bolts and nuts ground connections etc 5 2 Analysis If there is still a problem after the troubleshooting procedures see part 6 conta...

Page 15: ...t defective Control replace the lamp Defective micro switches Change the micro switch es Electrical connection Check the connections Faulty power supply Replace the power supply The beam is not unifor...

Page 16: ...entre l appareil et une mati re inflammable 4 3 1 3 Conditions d utilisation 4 3 1 4 Suspension 5 3 1 5 C ble de s curit 5 3 2 Electrique 6 3 2 1 Lampe 6 3 2 2 Alimentation 7 3 3 Accessoires 8 3 3 1...

Page 17: ...taille appropri e ancr e l avant de l appareil Tenir compte de leur poids pour la charge d accrochage 11 Ne pas ouvrir l appareil sous tension 12 Attention Lampe et supports chauds Attendre que l appa...

Page 18: ...suspension 3 Poign e verrouillage de la lyre 4 R glage focus 5 Point d lingage 6 Bouton de verrouillage de la rotation de l appareil 7 Index de tilt 8 Syst me de verrouillage avant 9 Porte filtre avan...

Page 19: ...1716A Connecteur d alimentation IEC60309 6h 16A 2P T bleu P17 2 CF100 Coupe flux 4 volets mobiles 135x135mm sans c ble de s curit 3 872 Crochet Doughty Twenty clamp avec vis crou M10 pour tube 48 51mm...

Page 20: ...ositions d utilisation 3 1 2 Distance minimale entre l appareil et une mati re inflammable 3 1 3 Conditions d utilisation Minimum 40 C 104 F 5 C 41 F Indice de Protection international IP20 Utilisatio...

Page 21: ...il doit obligatoirement tre assur par une suspension auxiliaire lingue cha ne convenablement dimensionn e et ancr e l arri re de l appareil La liaison devra tre effectu e au plus court au besoin avec...

Page 22: ...2 vis A de la trappe lampe 2 Retirer la trappe lampe 3 Positionner la lampe dans la douille 4 Remettre la trappe en position en s assurant que le fil de liaison terre soit bien l int rieur du projecte...

Page 23: ...C ble Longueur C blage 1 Version standard H07RNF 3G1 5 1 5 m 4 9 ft Phase marron Neutre bleu Terre jaune vert Puissance Mod le Tension Fr quence Courant 525 230 V 50 Hz Lampe 1 2 A Mat riel de classe...

Page 24: ...FR FR 8 3 3 Accessoires Etape 1 Etape 2 3 3 1 Porte filtre 3 3 2 Coupe flux...

Page 25: ...FR FR 9 4 1 2 Contr le Angle minimal Angle maximal Angle de faisceau 45 33 Angle de champ 28 56 Angle de faisceau 50 Angle de Champ 3 4 Op ration 4 1 Intensit lumineuse 4 1 1 Etendue...

Page 26: ...FR FR 10 4 2 Orientation 4 2 1 Etendue Fonction Etendue PAN 0 360 TILT TU 0 55 TD 0 90 4 2 2 Contr le PAN TILT...

Page 27: ...eaf 2 leaves 3 leaves 4 leaves Open FR 11 4 3 Couleur Couleur fixe Type Filtre g latine couleur ou effet standard Dimensions Installation Cf 3 3 1 unit s mm 4 4 Contr le de la forme du faisceau 4 4 1...

Page 28: ...s de jeu dans les contacts Pas de pi ces manquantes V rifier le serrage de toutes les pi ces m caniques vis crous mise la terre etc 5 2 Analyse Si le probl me persiste apr s avoir suivi la proc dure d...

Page 29: ...ectueuse Remplacer V rifier la lampe Mini rupteur d fectueux Remplacement du des mini rupteur s Connexion lectrique V rifier les connexions Alimentation d fectueuse Remplacer l alimentation Le faiscea...

Reviews: