background image

Quality in Any Language

TM

n

  

Reduce dirt build-up on burners and

  extend life of heat exchanger with  
  separated combustion units.

n

  

Installation and operation flexibilty 

  with rear or top air and flue connections   
  (Models UHA 30 - 125 only). 
 

n

  

Ideal for smaller spaces with low profile 

  design (Models UHA 30 - 125 only).

 

Reliable ignition with direct spark 

  ignition burners.

n

  

Minimize summer heat build-up  

  with remote fan operation. 

n

  

Longer life and less maintenance with  

  optional stainless steel heat exchangers.

n

  

Variable air throw direction with adjustable 

  horizontal louvers and optional adjustable 
  vertical louvers.

UHA Models 150 - 400

t

UHA Models 30 - 125

t

Combat

®

 UHA - Series

 Axial Fan Tubular Unit Heaters

1.800.828.7450

Summary of Contents for Combat UHA 30 - 125

Page 1: ...paces with low profile design Models UHA 30 125 only n Reliable ignition with direct spark ignition burners n Minimize summer heat build up with remote fan operation n Longer life and less maintenance with optional stainless steel heat exchangers n Variable air throw direction with adjustable horizontal louvers and optional adjustable vertical louvers UHA Models 150 400 t UHA Models 30 125 t Comba...

Page 2: ...enter of Flue in 2 5 2 5 2 5 2 5 2 5 2 5 Recommended Mounting Height to Heater Base ft 10 10 12 12 20 20 Clearances to Combustibles Low Profile UHA Range Models 30 125 Above Heater 1 Below Heater 0 To Side of Heater 1 To Rear of Heater 18 Airflow Clearance To Front of Heater 118 Access Side Door 18 Access Clearance To Flue 2 Combat UHA30 UHA125 ClearanceandDimensionData ...

Page 3: ...e Center in 6 6 6 6 6 7 7 7 H Position of Flue in 4 5 4 5 4 75 4 75 4 75 4 9 4 9 4 9 J Gas Inlet Position in 5 9 5 9 5 9 5 9 5 9 8 7 8 7 8 7 K Electrical Supply Position in 3 4 3 4 3 4 3 4 3 4 6 2 6 2 6 2 Maximum Recommended Mounting Height to Heater Base ft 20 20 25 25 25 30 30 30 Clearances to Combustibles Standard UHA Range Models 150 400 Above Heater 6 Below Heater 3 To Side of Heater 6 To Rea...

Page 4: ...ost commercial and industrial heating applications However in certain environments particularly where there is a chlorinated atmosphere e g near degreasing plant or other solvent processes or a particularly dusty atmosphere specialist advice should be sought at the design stage Roberts Gordon reserves the right to alter product specification details without notice Installation Code and Annual Insp...