SECTION 11: O
PERATION
AND
M
AINTENANCE
29 of 57
Fi
g
ure 14: Automatic Burner Control Se
q
uence
Fi
g
ure 15: Sin
g
le Sta
g
e Gas Valve for Models UHD[X][S][R] 150 – 400
Burner Se
q
uence for Ignition Control
Flame Signal
Start Gas Val
v
e
Ignition Spark
Thermostat 24 V
SHUT DO
WN
RU
N
START
ts = 10 Seconds
Signals Output By Control
Re
q
uired Incoming Signals
Flue Blower
Pressure
Switch
P
C
N
O
N
C
30 Seconds Purge*
*Purge time
b
egins at pressure switch change o
v
er.
30 Seconds Post Purge
If at any stage the flame fails, the control
w
ill retry
for ignition. The control has fo
u
r trials for ignition
before a one ho
u
r locko
u
t.
½PSI
I
N
C
O
N
OFF
Regulator
Outlet
Pressure
Gas Inlet
Inlet Pressure
TOP VIEW
END VIEW
Description
Part Number
Gas
V
alve 150 - 250 NG
90032505
Gas
V
alve 150 - 250 LP
90032506
Gas
V
alve 300 - 400 NG
90032520
Gas
V
alve 300 - 400 LP
90032521