UHD S
TANDARD
D
UCT
F
URNACE
I
NSTALLATION
O
PERATION
AND
S
ERVICE
M
ANUAL
42 of 57
SECTION 15: REPLACEMENT PARTS
See
w
arnings and important information
on Page
33, Section 13
before removing or replacing parts.
Burner Components
All serviceable b
u
rner parts are accessed by the
hinged door on the side of the heater.
15.1 Gas Valve
Remove the gas s
u
pply pipe at the heater inlet.
Follo
w
instr
u
ctions
on Page 43, Section 15.2
through Page 45, Section 15.3.1
to remove gas
valve/manifold.
Replace in reverse order.
V
erify that the gas flo
w
direction of the valve is correct. Use a minim
u
m
amo
u
nt of gas seal on the thread joint. Check that
all the joints are leak free. Reset gas valve.
See
Page 31, Section 11.2.3
.
IT IS IMPORTANT THAT ONLY THE CORRECT
GAS VALVE IS USED WHEN REPLACING THESE
CONTROLS.
Carbon Monoxide Hazard
WARNING
Use only genuine ROBERTS GORDON
®
replacement parts per this installation, operation and
service manual.
Failure to follow these instructions can result in death, electric shock, injury or property damage.
Explosion Hazard
DANGER
Electrical Shock Hazard
Fire Hazard
Single Stage
Gas Valve
Two Stage
Gas Valve
½PSI
I
N
C
O
N
OFF
½PSI
I
N
C
O
N
OFF
LO
HI
Description
Part Number
Single Stage Gas
V
alve, NG (Models UHD[X][S][R] 150 - 250)
90032505
Single Stage Gas
V
alve, LP (Models UHD[X][S][R] 150 - 250)
90032506
Single Stage Gas
V
alve, NG (Models UHD[X][S][R] 300 - 400)
90032520
Single Stage Gas
V
alve, LP (Models UHD[X][S][R] 300 - 400)
90032521
T
w
o Stage Gas
V
alve, NG (Models UHD[T][X][S][R] 150-250)
90032530
T
w
o Stage Gas
V
alve, LP (Models UHD[T][X][S][R] 150-250)
90032531
Summary of Contents for Combat UHD-Series
Page 2: ......
Page 4: ......
Page 8: ......
Page 46: ...UHD STANDARD DUCT FURNACE INSTALLATION OPERATION AND SERVICE MANUAL 38 of 57 14 1 General ...
Page 64: ...UHD STANDARD DUCT FURNACE INSTALLATION OPERATION AND SERVICE MANUAL 56 of 57 ...
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......