CRV-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
20 of 83
Step 7.1 Tube Installation
Step 7.2 Couplin
g
and Tube Assembly
Combustion
Chamber
7' 6"
(229 cm)
Combustion
Chamber
NOTE:
Tubing requires a downward slope of
1/2" (13 mm) per 20' (6 m) away from
burner. Tailpipe tubing requires a
downward slope of 1" (26 mm) per
20' (6 m) away from burner.
10'
maximum
(3 m)
End View
Weld
Seam
Bottom
of Tube
Hanger
Turnbuckles
Tube
Description
Part Number
T
u
be
91409XXX
T
u
rnb
u
ckle
91903201
T
u
be/Reflector Hanger
03090100
Tube
Tube
Orient coupling so that
the impact block is in the
2:00 or 10:00 oclock
positions.
Closed
Open
Tab
3" (8 cm) to
4" (10 cm)
Slide Bar/Coupling Lock
Coupling
Wide End
Coupling
Tube
Slide Bar/Coupling Lock
A
Close co
u
pling
w
ith tab.
B
Start slide bar/co
u
pling lock
onto co
u
pling.
C
Insert t
u
bes into co
u
pling.
D
Tighten co
u
pling to join t
u
bes.
Description
Part Number
Co
u
pling
01329600
Slide Bar/Co
u
pling Lock
01329700
T
u
be
91409XXX
Summary of Contents for CoRayVac CRV-B-10
Page 2: ......
Page 4: ......
Page 6: ......
Page 71: ...SECTION 13 STARTING THE SYSTEM 65 of 83 FIGURE 42 Vacuum Reading ...
Page 81: ...SECTION17 TROUBLESHOOTING 75 of 83 17 1 Troubleshooting Flow Chart ...
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......