FIGURE 21: EP-300 Series Horizontal Ventin
g
Confi
g
urations
10' (3 m) Maximum and 1 Elbow
Approved
Thimble
Vent Terminal
Tjernlund VH1-
6" (15 cm)
or Equivalent
(Not Included)
6" (15 cm)
Bird Screen
(Included)
18" (46 cm) Minimum -
40" (102 cm) Maximum
10' (3 m) Maximum and 1 Elbow
6" (15 cm)
Band Clamp
Single Wall Pipe/Tube 6" (15 cm)
Pitch single wall pipe
downward away from
pump 1/4" ( 6 mm) for
every 10' (3 m).
Part Number
Description
Part Number
Description
01330203
Tee, 4" (10 cm) Aluminized
90502100
Vent Terminal, 4" (10 cm) (Combustible Wall)
01330204
Tee, 6" (15 cm) Aluminized
90502101
Vent Terminal, 6" (15 cm) (Combustible Wall)
01331900
Damper Coupling, 4" (10 cm)
90502302
Vent Cap, 6" (15 cm) Metalbestos
01335801
Elbow, 4" (10 cm) Aluminized 90°
91409403
Tube, Aluminized 4" (10 cm) dia. 10' (3 m)
01397400
Bird Screen, 6" (15 cm)
91409420
Tube, Aluminized 6" (15 cm) dia. 10' (3 m)
02537801-1P Vent Terminal (Non-Combustible Wall)
91412800
Flexible Boot, 4" (10 cm)
02718851
Drain Cap, 4" (10 cm)
91412802
Flexible Boot, 6" (15 cm)
02718852
Drain Cap, 6" (15 cm)
91418200
Tube Adapter, 6" (15.2 cm) dia. x 4" (10 cm) dia.
01327002
Condensate Neutralization Tube 200
91901300
Boot Clamp, 4" (10 cm)
01327003
Condensate Neutralization Tube 600
91913703
Boot Clamp, 6" (15 cm)
01327004
Condensate Neutralization Tube 1000
E0009356
Damper Coupling, 6" (15 cm)
01327005
Condensate Neutralization Tube 2000
T0100320
Elbow, 6" (15 cm) Aluminized 90°
Summary of Contents for CoRayVac CRV-B-10
Page 2: ......
Page 4: ......
Page 6: ......
Page 71: ...SECTION 13 STARTING THE SYSTEM 65 of 83 FIGURE 42 Vacuum Reading ...
Page 81: ...SECTION17 TROUBLESHOOTING 75 of 83 17 1 Troubleshooting Flow Chart ...
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......