8.2 Home Screen and Programming the System
The following instructions provide a general overview
of programming your system. Each controller on the
network must be programmed separately. When pro-
gramming for controller is complete, select the
home
icon
to return to the
System View
screen. Select the
next controller on the network and repeat the pro-
gramming instructions. For detailed instructions,
please refer to the CORAYVAC
®
/COMPLETE™ Mod-
ulating Heating Control installation and operation
manual.
Home Icon
Note:
Prior to programming the system, ensure that
Initial Touchscreen Setup has been complete,
.
Home Screen Map
Note:
For detailed touchscreen navigation, reference
the Touchscreen Navigation Tree, located on
.
8.3 Home Screen System Configuration
From the Home screen select
<menu>
to access the
list of property menus. Scroll down and select
<Configuration - Service>
.
The
Configurations-Service
screen is used to
adjust how many zones, vacuum pumps, and the
type of heating system that is connected to the con-
troller you are programming.
Select the box next to
'Number of Zones'
and set
the number of zones connected to that controller.
Select the box next to each
'Zone "#" Selection'
and
choose the type of heating system that is associated
with that zone.
Example 1:
If the controller is controlling two
CORAYVAC
®
systems with a combination of four
heating zones, the user must assign which vacuum
pump is associated with each zone. If zones 1 and 2
are connected to vacuum pump 1, then set
'Zone 1
Selection'
and
'Zone 2 Selection'
both to
<Vacuum
Pump 1>
. Set
'Zone 3 Selection'
and
'Zone 4
Selection'
to
<Vacuum Pump 2>
.
Example 2:
If the controller is controlling unitary
heaters, select
<Unitary Modulating>
or
<Unitary
On/Off>
(depending on what type of unitary heater is
installed) to the appropriate
'Zone "#" Selection'
.
To Home Screen
To Alarm Manager Screen
To Access Individual
Zone Temperature
and Setpoint
Configuration Screens
Pump On/Off
and Run % Status
Outside Air
Temperature
To Access
List of All Active
and Inactive Alarms
To Access List of
Property Menus
Summary of Contents for CORAYVAC
Page 2: ......
Page 4: ......
Page 69: ...SECTION 8 PROGRAMMING AND TROUBLESHOOTING THE SYSTEM 65 THIS PAGE LEFT INTENTIONALLY BLANK ...
Page 71: ...SECTION 9 TROUBLESHOOTING 67 FIGURE 26 Vacuum pump does not turn on ...
Page 75: ...SECTION 9 TROUBLESHOOTING 71 FIGURE 31 Burner troubleshooting in manual mode ...
Page 77: ...SECTION 9 TROUBLESHOOTING 73 After 45 second prepurge burners do not light continued ...
Page 81: ...SECTION 9 TROUBLESHOOTING 77 FIGURE 36 Air Pressure Switch alarm ...
Page 83: ...SECTION 9 TROUBLESHOOTING 79 FIGURE 38 Repeater troubleshooting ...
Page 85: ...SECTION 9 TROUBLESHOOTING 81 BACnet MS TP troubleshooting continued ...
Page 109: ...SECTION 13 TOUCHSCREEN TREE 105 Touchscreen Tree Overview continued ...
Page 111: ...SECTION 13 TOUCHSCREEN TREE 107 FIGURE 47 Maintenance Unit FIGURE 48 Alarms ...
Page 113: ...SECTION 13 TOUCHSCREEN TREE 109 FIGURE 51 Configuration Zones FIGURE 52 Configuration Unit ...
Page 115: ...SECTION 13 TOUCHSCREEN TREE 111 FIGURE 55 Touchscreen System FIGURE 56 Touchscreen Setup ...
Page 118: ...ROBERTS GORDON CORAYVAC MODULATING HEATING CONTROL CONTROLLER INSTALLATION MANUAL 114 ...