Quick Start Installation Manual

111-326C

Installation DOs and DON’Ts

DO
• 

Shut off all power to system before installing.

• 

Read entire manual before installing.

• 

Make sure that all wiring conforms to national and
local codes.

DO NOT
• 

Install on voltages greater than 30 VAC.

• 

Short jumper across terminals on the gas valve or at the
system control.

• 

Connect ground to any terminal in this unit.

• 

Install on outside walls or in direct sunlight.

Recycling Thermostat

If this thermostat REPLACES a thermostat that contains mercury,

DO NOT discard the old thermostat in the regular trash.  Mercury is harmful
to humans and the environment.  For this reason, do not open, break, or
crush the mercury cell.  If mercury leaks from a damaged cell, DO NOT
touch or handle mercury with bare hands.  Use protective, non-absorbent
gloves to place mercury into a sealable container.  Fill the container with
sand or another absorbent material and seal the container completely.

Return the mercury or mercury products, in a sealed container, to Invensys
Climate Controls or a local recycling center for proper disposal.  If you have
any questions, call Robertshaw technical support at 1-800-445-8299.

Invensys Climate Controls
28C Leigh Fisher Blvd.
El Paso, TX 79906
Attn: Mercury Recycling Center

Select location for installation.

1

Open the case with a screwdriver. Place
in slot and gently pry forward at all four
locations.
Lift cover straight off. Do not pivot on
upper or lower retaining clips.

2

Mark mounting hole locations on wall.

3

Drill  

3

/

16

” holes at marked locations on

wall. Insert plastic anchors into holes.

4

Align unit base over plastic anchors
embedded in wall and secure with the
screws provided.

5

Connect wiring between unit and 
furnace. For Model 9901i (1H/1C 
furnace applications).

6

Cut

out

opening

a

b

1/4"

1-1/2"

1"

1

2

3

4

Mark mounting hole 
locations on wall using 
unit base as template.

Drill 3/16  holes

a

b

Press anchors into holes until flush.

Y1

R

C

E/W1

A1 O B G

Thermostat

C   - 24VAC Common
R   - 24VAC
Y1 

-  1st stage cooling

E/W1 -  1st stage heating
O   - Not used
B   - Not used
G   - Fan
A1 - 

Aux 

contact

A2 - 

Aux 

contact

W2  - Not used
Y2 

- Not used

L   

- Not used

TERMINAL DESIGNATIONS

C

R

Y

W

G

B

O

9901

i

W2

A2

Y2

L

Equipment Wiring 
Terminals
Please refer to 
furnace installation 
manual for proper 
terminations

Remove 1/4” of insulation
from end of each wire

DELUXE
PROGRAMMABLE
THERMOSTATS