background image

SC-888 Instructions 

Thank you for buying the Robic SC-888

.  Your purchase brings you a world class timer with a vast array 

of advanced timekeeping functions. 

Please take a moment to review this operating guide, so that you can become familiar with the SC-888’s 
many capabilities and how you can best access them for your maximum benefit. 

The SC-888 can be configured to operate as a 

Single

 (T-1), 

Double

 (T-2) or 

Triple

 (T-3) timer within the 

Chronograph (stopwatch), Speed and Countdown timer modes.  

Single, Double 

or

 Triple

 refers to the SC-

888’s ability to time one, two or three activities or competitors at once. 

Certain pushbuttons perform different operations, depending on how the timer is configured.  The other 
pushbuttons operate the same in all (ALL) modes.  

Single

:  T-1;  

Double

:  T-2;  

Triple

:  T-3. 

The following illustration provides the operation of pushbuttons and location of indicators for the Robic 
SC-888. 

 
 

(B)

(T-1) Lap/Split 

Reset 

(T-2)/(T-3):  Start –  Lap/Split – 
Stop #2 
ALL:  Reset to zeros 

(D)

 ALL: Backlight 

(F)

ALL:  Recall, Set

Memory Up or Down

(E)

 

ALL:  Change Mode (Mode/Select) 
Release to Running Time 

(C)

ALL: Advance

(T-3):  Start 

Lap/Split 

Stop #3

(A)

(T-1) Start Stop

(T-2)/(T-3) Start 

Lap/Split

Indicators:  Above the top row: 

Recall 

 

 Maximum/  

  Slowest     Memory  Speed 

Direction           Average 

 Fastest Lap 

Lap        Recall 

Timer      Chrono       Mile 

Kilometer 

   

    

 

  AVG 

  MAX 

 SLOW 

RCL     SPEED   CHR    MILE      KM 

Summary of Contents for SC-888

Page 1: ...three activities or competitors at once Certain pushbuttons perform different operations depending on how the timer is configured The other pushbuttons operate the same in all ALL modes Single T 1 Dou...

Page 2: ...r kilometer Timers can be started separately or simultaneously Recall of the previous 150 readings for each timer Displays lap time speed and number for each timer Memory recall in either ascending or...

Page 3: ...back to Alarm Hours 12 24 HOUR OPTION The time may be set to operate in AM PM hours 1 12 or on a 24 hour basis hours 0 24 To set the 12 or 24 hours press E after setting the Day and either 12H or 24H...

Page 4: ...ctions Memory Recall Direction You may review up to the 150 previous readings in either Up ascending 1 2 3 149 150 or Down descending 150 149 3 2 1 order UP or Down indicators appear on the far left a...

Page 5: ...refer to Part III above to review the various options available in setting up configuring your SC 888 Chronograph Select the desired option when it appears flashing From the Reset position press and h...

Page 6: ...will appear on the left side of each row 1 Top row only Single 2 Top and middle rows are Double 3 All three rows are Triple Independent or Simultaneous Start SEP indicator will appear below the bottom...

Page 7: ...es The lap time will appear frozen in the upper row the split time will appear frozen in the middle row The current running LAP or SPLIT time will appear in the bottom row Take as many lap split readi...

Page 8: ...ster each time a reading is taken You may press E to release the display to the current running time or the SC 888 will automatically do so after 15 seconds Upon release of the previous reading the la...

Page 9: ...essed within 15 seconds You may escape the recall procedure at any time by pressing E If the timer is running simply press the appropriate pushbutton to take a new time reading or stop the timer s IMP...

Page 10: ...dvance for tens units tenths hundredths and thousandths Exit the setting procedure at any time by pressing F or After entering the distance press E SPd 1 2 3 appears in the middle row You may select f...

Page 11: ...p STOP appears Press B to Reset Using the SC 888 as a Double or Triple Speed Timer Use pushbutton A for Speed Timer 1 Use pushbutton B for Speed Timer 2 Use pushbutton C for Speed Timer 3 C Speed Time...

Page 12: ...et all speed timers to zero ADVANCED FUNCTIONS The fastest MAX slowest SLOW and average AVG lap times and speeds can be displayed while the Speed Timer is running or stopped by pressing F The correspo...

Page 13: ...n be entered The CDT has a resolution of 1 10 second There is a LOOP option which allows the CDT to automatically sequence through each countdown time upon completion of the previous preset time Do no...

Page 14: ...a single timer is selected Should you want a single preset time to automatically repeat select RPT during the set up procedure Operating the Countdown Timer s The Countdown Timer will not operate unl...

Reviews: