background image

WARNING:

The distance between the hob and the mounting holes of the canopy to be at least 860mm for 600 and 

870mm (RCT) or 880mm for 900 models to ensure that the fully installed canopy has a clearance of 700mm 

(recommended height) between the lower part of the hood and the cooking hob. 

(1) Before drilling any holes check the wall and the ceiling are clear of any electrical cables, pipes etc. Fixing to a 

solid stud is recommended. 

(1) Fix the mounting washers in position shown in diagram. (1) Check with spirit level across the washers to ensure 

they are level.

Installing Ducting

NOTE: 

All ducting must comply with local requirements and building codes.  

Mark the position of decorative chimney at ceiling and wall, cut cornice moulding away if necessary to enable panels 

to fit flat against the wall and ceiling. 

(2) Mark and cut the hole in the ceiling to fit the ducting (130 to 140mm dia). 

(3) This is positioned centrally with the canopy and 80mm from the wall.

Installation 

continued

Installing Ceiling Bracket

Using the supplied screws, fix the ceiling bracket (4) to the wall, checking that it is aligned with the hood.

Summary of Contents for RCT600SS

Page 1: ...Description Robinhood Canopy Model Numbers RCT600SS RCT600WH RCT900SS RCT900WH All dimensions are in mm Model may vary slightly from images pictured ...

Page 2: ...Exhaust air must not be discharged into a heating flue or wall cavity unless the cavity is designed for that purpose o Areas where the rangehood is installed that also have gas oil or coal fired heaters must be well ventilated to prevent a partial vacuum in the room This includes gas hobs A partial vacuum in the room could result in too high a concentration of gas in the atmosphere o The appliance...

Page 3: ...ble after installation Please read in conjunction with following diagrams The unit is designed for 2 4 to 2 7 metre high ceiling The decorative chimney cover is telescopic and is designed for 550 to 850mm adjustment Note Ducting accessories are not supplied Please refer to the optional ducting kits The air outlet from the motor requires 125mm round ducting which requires 135mm diameter round hole ...

Page 4: ...rs in position shown in diagram 1 Check with spirit level across the washers to ensure they are level Installing Ducting NOTE All ducting must comply with local requirements and building codes Mark the position of decorative chimney at ceiling and wall cut cornice moulding away if necessary to enable panels to fit flat against the wall and ceiling 2 Mark and cut the hole in the ceiling to fit the ...

Page 5: ...power supply Check function of rangehood lights and motor before continuing assembly Level the hood and fix with safety screws 6 Connect 125mm ducting to top of motor flange and secure 7 Assemble the telescopic ducting covers 8 to accurately suit the dimension required 9 and secure with screws plastic cup washers and plastic caps to the top and bottom of the chimney in 4 places ...

Page 6: ...aning or maintenance To prevent surface damage never use abrasive or oil based liquid cleaners To clean the surfaces of the appliance use mild detergent and warm water In areas of high humidity and coastal environments cleaning should be carried out frequently Warning a build up of oil may occur if the rangehood is not cleaned regularly Filter Maintenance To maintain efficient the filter should be...

Page 7: ... is a fire risk if cleaning is not carried out in accordance with the instructions o Do not flambé under the rangehood o Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels o The minimum distance between the hob surface and the lowest part of the rangehood is 600mm This distance shall be at least 650mm if the rangeh...

Page 8: ...cleaners Heat damage including from washing the product at high temperatures Impact or mishandling the product including the impact caused by objects scraped along thrown or dropped on the product surface or excessive weight being placed on the product Structural or support changes in or affecting the building or the application where the product has been installed Failure to clean or maintain the...

Page 9: ...eat damage including from washing the product at high temperatures Impact or mishandling the product including the impact caused by objects scraped along thrown or dropped on the product surface or excessive weight being placed on the product Structural or support changes in or affecting the building or the application where the product has been installed Failure to clean or maintain the product a...

Reviews: