Installation
•
Mounting the Rangehood
•Fit the ducting adaptor to the rangehood using the short screws supplied.
•Provide an opening on the underside of the cupboard to suit models/ provide 490mm x 258mm for
600 model or 665mm x 258mm for 900 model.
•Remove both LED Bulbs from their sockets.
•Remove the face plate of the rangehood by undoing the two visible screws located on both side-
ends. Eight mounting holes around the unit then are accessible.
•Lift the rangehood and fit through the opening of the cupboard. Secure unit using long screws
supplied. Refit face plate, then refit the LED bulbs
Model may vary slightly from images
pictured
Recirculation mode
1.
This unit can be installed to operate in recirculation mode where ducting is not a
chosen/desired or practical option. Ducting may still be required to vent air from a
cupboard cavity. Ensure that the top ducting outlet is not obstructed. Even a partial
obstruction will restrict the efficiency of the rangehood.
Replace aluminium filters with charcoal filters (Pg. 6 Parts & Accessories list).