9
Cleaning and Maintenance
BULB REPLACEMENT
Important:
•
The bulb must be replaced by the manufacturer, its service agent, or similarly qualified persons.
•
Always switch off the electricity supply before carrying out any operations on the appliance. When
handling bulb, make sure it has completely cooled down before any direct contact with hands.
•
When handling bulbs hold with a cloth or gloves to ensure perspiration does not meet the bulb as this
can reduce the life of the bulb.
Note:
•
Before changing the lights, make sure that the appliance is turned off and unplugged.
•
Protect against danger when changing lights, such as wearing gloves.
Changing the lights:
•
Remove the grease filter.
•
Use a tool or the hand to press the spring splinter of both sides of LED light to the inside, until the light
is pressed out, see pic 1. Then slightly pull the light connecting wire out and dismantle the terminal of
the light connecting wire. See pic 2.
•
Apply the reverse procedure to install the light back.
ILCOS D code for this lamp is: DSR-1.5/65-S-64
LED modules –round lamp
Max wattage: 2×1.5 W
Voltage range: DC 12V
Dimensions: