background image

 

 

Cleaning 

SAFETY PRECAUTION 

Before cleaning your rangehood or performing any maintenance, please ensure that the rangehood is turned off at the 

power point. 
Do not use abrasive cleaners to clean the rangehood. The use of warm soapy water and a cloth are recommended. 
Ensure that the rangehood is cleaned regularly, as a build‐up of grease and fat may occur otherwise. 
The filters on the rangehood must be cleaned regularly to maintain efficiency, and prevent grease build up. The filter 

mesh is made of a high density Stainless Steel. It is recommended that this is undertaken every 4 – 6 weeks, depending 

on frequency of use. The filters can be cleaned with warm soapy water or a cloth. 
Cleaning of the rangehood must be performed as described above; otherwise there is a possibility of a fire hazard due 

to grease and fat build up. 

Troubleshooting 

Fault 

Possible Cause 

Solution 

Light on, but motor 

does not work 

Fan switch turned off 

Select a fan switch position. 

Fan switch failed 

Contact Everdure Service. 

Motor failed  

Contact Everdure Service. 

Light does not work, 

motor does not work 

House fuses blown 

Reset/Replace fuses. 

Power cord loose or disconnected 

Refit cord to power outlet. 

Switch power outlet on. 

Oil leakage 

One‐way valve and the air ventilation 

entrance are not tightly sealed 

Take down the one‐way valve and seal with 

sealant. 

Leakage from the connection of U‐

shaped section and cover 

Take U‐shaped section down and seal. 

Lights not working 

Broken/Faulty LED lamp 

Contact Everdure Service. 

Insufficient suction 

The distance between the rangehood 

and the gas top is too far  

Refit the rangehood to the correct distance. 

The Rangehood 

inclines 

The fixing screw not tight enough 

Tighten the hanging screw and make it 

horizontal. 

 

Summary of Contents for RUM52XCOM

Page 1: ...Installation and Operating Instructions Model Number RUM52XCOM Description 52cm Under mount Rangehood ...

Page 2: ...instructions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Shriro reserves the right to alter specifications or appearances without notice Important Safety Instructions 1 Appliance Details 2 Installation Instructions 3 Operating Instructions 3 Light Replacement 3 Cleaning 4 Troubleshooting 4 Warranty...

Page 3: ...oor use only 12 It is recommended to operate the range hood prior to cooking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours 14 Turn off the range hood when not in use 15 Do not use the range hood if it is damaged especially the supply cord and the case 16 Do not immerse the range hood ...

Page 4: ...2 Appliance Details Voltage 220V 240V 50Hz Rated input power 196W Lamp Max 2 x 3W GU10 LED ...

Page 5: ... 265 mm for model RUM52XCOM 3 Make sure the distance between the edge of the hole and the edge of the cupboard edge is at least 35mm Take down the filter and remove the four screws on the panel 4 Use random accessory tighten screws fix the hood into cabinet 5 Use 4 screws fix the panel into body and equip the filter 6 Install one way valve put the one way valve into air outlet Put on the one way v...

Page 6: ...a possibility of a fire hazard due to grease and fat build up Troubleshooting Fault Possible Cause Solution Light on but motor does not work Fan switch turned off Select a fan switch position Fan switch failed Contact Everdure Service Motor failed Contact Everdure Service Light does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to po...

Page 7: ...mile 1800 628 577 Email customercare shriro com au www robinhood com au Attention Customer Services Manager Warranty exclusions 1 The warranty does not apply where in Shriro s opinion The defect is caused by misuse wear and tear dirt fire or accidental damage The product has been repaired or serviced by an unauthorised person The product was not installed in accordance with our instructions The pr...

Reviews: