12
Never remove this riving knife. Kickbacks are severe and very dangerous !!
Lower sawblade cover
In the event of a saw blade change, the sliding table must be pushed fully to the rear in order to be
able to open the saw blade cover.
The sawblade cover is held by 2 magnets.
If the cover is open, the saw cannot be started.
Adjusting the main sawblade
M500
(Fig.12A-B)
The main saw blade can be adjusted vertically with the handwheel (1) and the handle (2
The height adjustment of the scoring saw is done with the adjusting knob (5). (fig 12A)
Lock the setting with the serrated nut (4). (fig 12A)
The desired cutting angle can be set with the handwheel (1) and the handle (2)(Fig 12B). The angle
setting can be read on the clock (4) in the handwheel. The angle of the scorer blade is automatically
adjusted according to the angle setting of the main saw blade. The sawing unit can be adjusted to
angles between 45 ° and 90°. Mechanical stops have been adjusted from the factory to the end points.
Fig.12A
Fig.12B
Summary of Contents for M500 EL
Page 6: ...6 General dimensions...