background image

5

GB

Thank you for buying a Roblin product which has been manufactured to the highest quality standards to
meet your requirements.
We recommend you carefully read this booklet in which you will find instructions for installation, hints for
use and maintenance.

1

ELECTRICAL

This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug.

Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm

minimum contact gap on each pole.

Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on

the rating plate inside the cooker hood.

Technical Specification: Voltage 220-240, single phase ~50/60Hz.

2

 INSTALLATION ADVICE

Ensure the cooker hood is fitted in compliance with the recommended fixing heights.

To ensure the safe operation of this cooker hood, we recommend that the hood should not be fitted

below 65cm (for electric) or (70cm for gas) the measurements taken from the surface of the cooking
appliance to the underside of the cooker hood.

It is a possible fire risk if the hood is not sited as recommended.

To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles

on the underside of the cooker hood and the cooker hood should be positioned away from doors and
windows, which will create turbulence.

Ducting

If the room where the hood is to be used contains a fuel-burning appliance such as a central heating

boiler then its flue must be of the room sealed or balanced flue type.

If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the

room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement
equivalent to the diameter of the ducting being fitted, if not larger.

The ducting system for this cooker hood must not be connected to any existing ventilation system,

which is being used for any other purposes or to a mechanically controlled ventilation ducting.

The ducting used must be made from fire retardant materials and the correct diameter must be used,

as incorrect sized ducting will affect the performance of this cooker hood.

When the cooker hood is used in conjunction with other appliances supplied with energy other than

electricity, the negative pressure in the room must not exceed 0.04 mbar to prevent the fumes from
combustion being drawn back into the room.

The appliance is for domestic use only and should not be operated by children or people who are

infirm without supervision.

This appliance must be positioned so that the wall socket is accessible.

3

FITTING

Any permanent electrical installation must comply with the latest regulations concerning this type of
installation and a qualified electrician must carry out the work. Non-compliance could cause serious
accidents or injury and would deem the manufacturers guarantee null and void.

IMPORTANT - 

The wires in this mains lead are coloured in accordance with the following code :

 green / yellow : earth

blue : neutral

  brown : live

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
-

The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter 

E

 or by the earth symbol  

      or coloured green or green and yellow..

-

The wire  which is coloured blue must be connected to the terminal which is marked with the letter 

or

coloured black.

-

The wire  which is coloured brown must be connected to the terminal which is marked with the letter 

or

coloured  red.

Summary of Contents for DECLIC 609

Page 1: ...ET D UTILISATION INSTRUCTIONS FOR INSTALLATION AND DIRECTIONS FOR USE MONTAGE UND GEBRAUCHSANWEISUNG LIBRETTO DI ISTRUZIONI INSTRUCCIONES DE INSTALACION E UTILIZACION MONTAGE EN GEBRUIKSHANDLEIDING D...

Page 2: ...DECLIC 609 610 Composants Components Bauelemente Componenti Componentes Onderdelen...

Page 3: ...DECLIC 909 910 Composants Components Bauelemente Componenti Componentes Onderdelen...

Page 4: ...ALACION DEL APARATO FUNCIONAMIENTO CONSEJOS DE UTILIZACION MANTENIMIENTO GARANTIA Y ASSISTENCIA TECNICA NOTA GB CONTENTS 5 ELECTRICAL WIRING INSTALLATION ADVICE FITTING THE APPLIANCE OPERATION USEFUL...

Page 5: ...ppareil la hotte ne doit en aucun cas tre raccord e un conduit de ventilation m canique contr l e V M C Lorsqu on vacue l air vici dans un conduit d vacuation veiller ce que celui ci ne soit pas d j e...

Page 6: ...r apr s Recyclage L air filtr est evacu dans la pi ce travers une ouverture plac e sur la partie sup rieure du meuble ou de la hotte fig 10 Fixer l trier sur le corps par 3 vis M4 x 6 Fixer ensuite la...

Page 7: ...maximum les op rations d entretien synonyme de bon fonction nement et rendement de l appareil dans le temps D pose de la vitre Celle ci peut tre enlev e afin de faciliter son nettoyage Pousser la vit...

Page 8: ...l appareil inscrit sur la plaque signal tique situ e l int rieur de la hotte Seule la facture d achat de l appareil fera foi pour l application de la garantie contractuelle Cette garantie ne couvre p...

Page 9: ...sectional measurement equivalent to the diameter of the ducting being fitted if not larger The ducting system for this cooker hood must not be connected to any existing ventilation system which is be...

Page 10: ...t which will allow access via the cabinet door fig 7 9 Insert the grommets into the screw holes fig 8 10 Connect the ducting onto the round outlet on the top of the motor assembly 11 Connect both appl...

Page 11: ...USEFUL HINTS To obtain the best performance it is advisable to switch ON the cooker hood a few minutes in the boost setting before you start cooking and you should leave it running for approximately...

Page 12: ...this can only be replaced by at approved repair centre appointed by the manufacturer who have the necessary tools and equipment to carry out any repairs properly Repairs carried out by other persons w...

Page 13: ...25 2 1...

Page 14: ...26 3 4...

Page 15: ...27 8 5 DECLIC 609 610 A 514 mm B 255 mm DECLIC 909 910 A 814 mm B 255 mm A B 9 6 7...

Page 16: ...28 11 10 12...

Page 17: ...29 16 13 14 17 15...

Page 18: ...30...

Page 19: ...AU BROWN BRUN BRAUN GREEN YELLOW VERT JAUNE GR N GELB GREY GRIS GRAU LIGHT BLUE BLEU CLAIR HELL BLAU PINK ROSE ROSA PURPLE MAUVE MALVER FARBIG WHITE BLANC WEISS YELLOW JAUNE GELB Halogen S potlight e...

Page 20: ...onnectedtotheelectricitysupply viaadouble poleswitchhaving3mmminimumcontact gap on each pole A Switched Fuse Connection Unit to BS 1363 Part 4 fitted with a 3 Amp fuse is a recommendedmains supply con...

Page 21: ...33 GU10 50 W 230 V Code 12EC006 ACCESSOIRES ACCESSORI ACCESSORIES ACCESORIA ZUBEH RE ACCESSOIRES 5403003...

Page 22: ...34 A B C D E F F...

Page 23: ...35 G H I J K L...

Page 24: ...tique de la hotte Rating plate of the cookerhood Typenschild im Inneren der Dunstesse Etichetta all interno della cappa Etiqueta de la campana Typeplaatje van de afzuigkap Num ro de s rie Serial numbe...

Page 25: ...ies dass es von der Europ ischen Richtlinie 2002 96 EG erfasst wird Bitte informieren Sie sich ber die rtlichen Sammelstellen f r Elektroprodukte und elektronische Ger te Bitte beachten Sie die lokale...

Page 26: ...betekent dit dat het product conform is de Europese Richtlijn 2002 96 EC Gelieve u te informeren in verband met het plaatselijke inzamelingsysteem voor elektrische en elektronische apparaten Gelieve u...

Page 27: ...ntspricht den europ ischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europ ischen Richtlinien 89 336 EWG zur elektromagnetischen Vertr glichkeit und den Richtlinien 93 68 EW...

Reviews: