10
5 USEFUL HINTS
• To obtain the best performance it is advisable to switch ‘ON’ the cooker hood a few minutes (in the
boost setting) before you start cooking and you should leave it running for approximately 15 minutes after
finishing.
•
IMPORTANT: NEVER DO FLAMBÉ COOKING UNDER THIS COOKER HOOD
•
Do not leave frying pans unattended during use as over-heated fat and oil might catch fire.
•
Do not leave naked flames under this cooker hood.
•
Switch ‘OFF’ the electric and gas before removing pots and pans.
•
Ensure heating areas on your hotplate are covered with pots and pans when using the hotplate
and cooker hood simultaneously.
6 MAINTENANCE
Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply.
The cooker hood must be kept clean; a build up of fat or grease can be a fire hazard.
Casing
• Wipe the cooker hood frequently with a clean cloth, which has been immersed in warm water containing
a mild detergent and wrung out.
• Never use excessive amounts of water when cleaning particularly around the control panel.
• Never use scouring pads or abrasive cleaners.
• Always wear protective gloves when cleaning the cooker hood.
Metal Grease Filters
The metal grease filters absorb grease and dust during cooking to help keep the cooker hood clean
inside. The grease filters should be cleaned once a month or more frequently if the hood is used for more
than 3 hours per day.
To remove and replace the metal grease filters
• Remove the metal grease filters one at a time by releasing the catches on the filters; the filters can
now be removed.
• The metal grease filters should be washed, by hand, in mild soapy water or in a dishwasher.
• Allow to dry before replacing.
Active Charcoal Filter
The charcoal filter cannot be cleaned. The filter should be replaced at least every three months or more
frequently if the hood is used for more than three hours per day.
To remove and replace the filter
• Remove the metal grease filters.
• Press against the two retaining clips, which hold the charcoal filter in place and this will allow the filter
to drop down and be removed.
• Clean the surrounding area and metal grease filters as directed above.
• Insert the replacement filter and ensure the two retaining clips are correctly located.
• Replace the metal grease filters.
Extraction tube
.
Check every 6 months that the dirty air is being extracted correctly. Comply
with local rules and regula-
tions
with regard to the extraction of ventilated air.
Lighting
.
If the lamp fails to function check to ensure it is fitted correctly into the holder. If lamp failure has occurred
then it should be replaced with identical replacement.
Do not replace with any other type of lamp and do not fit a lamp with a higher rating.
7 GUARANTEE AND AFTER SALES SERVICE
• In the event of any malfunction or anomaly, notify your fitter who will have to check the appli-
GB
Summary of Contents for Escale 2 centrale 900
Page 17: ...A4 5 6 Composants Components Bauelemente Componenti Componentes Onderdelen R 7 8...
Page 18: ...A5 Colis Hotte Hood Parcel 1 2 4 3...
Page 19: ...A6 2a 7a 1 3 4 5 2b 220 210 50 50 50 50 50...
Page 20: ...A7 6a 6b 6c 7a...
Page 21: ...A8 7b 6c 2 1 2 3 2 2 1 3 2...
Page 22: ...A9 A 6d C 6 7...
Page 23: ...A10 8 9 7b 2 1 2 3 2 2 1 3 2...
Page 24: ...A11 10 11...
Page 27: ...A14 GU10 28 W 230 V Code 12EC024 3 4...
Page 29: ......
Page 30: ......
Page 31: ......