Summary of Contents for Lido 2 Murale

Page 1: ...urale Verre NL Instructions for use and installation Cooker Hood Istruzioni per l uso e l installazione Cappa Instrucciones de instalacion e utilizacion Campana Bedienungsanleitung und Einrichtung Dun...

Page 2: ...TALACION DEL APARATO FUNCIONAMIENTO CONSEJOS DE UTILIZACION MANTENIMIENTO GARANTIA Y ASSISTENCIA TECNICA NOTA GB CONTENTS ELECTRICAL WIRING INSTALLATION ADVICE FITTING THE APPLIANCE OPERATION USEFUL H...

Page 3: ...cas tre raccord e un conduit de ventilation m canique contr l e V M C Lorsqu on vacue l air vici dans un conduit d vacuation veiller ce que celui ci ne soit pas d j exploit v hiculer des gaz ou fum es...

Page 4: ...de l ensemble de la hotte verrouiller celle ci par une vis de fixation positive Rep 8 afin de garantir la s curit d accrochage 5 Raccordement Pour la version Evacuation Ext rieure a Mettre en place le...

Page 5: ...ent un un de fa on cyclique Appuyer sur la touche pour d sactiver F Active l arr t automatique apr s un d lai de 30 Id ale pour liminer compl tement les odeurs r siduelles Peut tre activ e depuis n im...

Page 6: ...rver les prescriptions r glementaires locales concernant l vacuation de l air vici clairage Avant toute intervention sur l appareil mettre l interrupteur d allumage des lampes en position teinte Ne pa...

Page 7: ...riques et lectroniques Veuillez agir selon les r gles locales et ne pas jeter vos produits usag s avec les d chets domestiques usuels Jeter correctement votre produit usag aidera pr venir les cons que...

Page 8: ...are fitted ensure that there is an adequate supply of fresh air to the room Ensure the kitchen is fitted with an airbrick which should have a cross sectional measurement equivalent to the diameter of...

Page 9: ...whether or not there is a raised back on the worktop The splashback is to be installed before installing the canopy If the splashback is to be fixed to the wall using both the top and bottom fixing ho...

Page 10: ...n spigot R onto the upper chimney wall bracket using the same fixing screws Fig 2 item 2 b Connect the ducting 150mm 6 INS not provided between motors item 6 and the recirculation spigot and secure th...

Page 11: ...It is disabled by pressing the Button F Activates automatic switch off with a 30 delay Suitable to complete elimination of residual odours Can be activated from any position it is deactivated by pres...

Page 12: ...requently if the hood is used for more than 3 hours per day To remove and replace the metal grease filters Remove the metal grease filters one at a time by releasing the catches on the filters the fil...

Page 13: ...use or neglect the replacement of any light bulbs or filters or removable parts of glass or plastic These items are considered to be consumable under the terms of this guarantee 8 REMARKS This applian...

Page 14: ......

Page 15: ...R RED ROUGE ROT W WHITE BLANC WEISS W P WHITE PINK BLANC ROSE WEISS ROSA Y YELLOW JAUNE GELB Brown Blue M N L1 F Blue Brown M 230 W L2 L2 MULTI FLACH KABEL LIMANDE COMMANDE FLAT CABLE ELEKTRONISCHE S...

Page 16: ...Connection Unit to BS 1363 Part 4 fitted with a 3 Amp fuse is a recommendedmains supply connectionaccessoryto ensure compliance with the Safety Requirements applicable to fixed wiring instructions The...

Page 17: ...3 Cr dence Option Splachback Optional R ckwand Optional Fondale Opzionale Panel Opcional Spatscherm Optie...

Page 18: ...8 175 8 175 8 8 9 898 1098 409 12 27 8 4 848 1048 405 A A...

Page 19: ...B...

Page 20: ...45 Composants Components Bauelemente Componenti Componentes Onderdelen 2 R 8 4 6 5 7 9...

Page 21: ...285 40 164 50 56 4 0 4 5 6 400 170 113 6 260 40 293 35 175 175 3 848 1048 670 200 3 H 400...

Page 22: ...359 285 40 164 50 56 4 0 122 6 4 5 473 752 mini maxi 1484 1205 898 1098 438 475 723 150 400 35...

Page 23: ...2 2 1 82 670 293 40...

Page 24: ...3 4 10 10 30 1070 260 4 A...

Page 25: ...A11 5 6 6 R 7a 7b...

Page 26: ...Composants Components Bauelemente Componenti Componentes Onderdelen A2 8 4 6 9 A3 A1 5 VIZIO 3 SMC...

Page 27: ...400 6 301 5 35 175 175 3 8 4 8 8 4 1 1 397 251 5 340 97 184 DESSOUS HOTTE PLAN TRAVAIL 41 5...

Page 28: ...4 VIZIO 3 900 SMC 475 4 5 6 473 898 470 285 175 88 42 359 4 0 438 400...

Page 29: ...VIZIO 3 1100 SMC 473 1098 438 475 175 359 6 4 5 285 42 88 470 4 0 400...

Page 30: ...7 397 400 301 5 251 5...

Page 31: ...8 4 10 10 301 5 25 5 1 4...

Page 32: ...ACCESSOIRES ACCESSORI ACCESSORIES ACCESORIA ZUBEH RE ACCESSOIRES 13MC070 323 x 262 x 8 mm 7 2 LR03 AAA 1 5V 1 3...

Page 33: ...e Numero de serie Serienummer Mod le Model Modell Modello Modelo Model Plaque Signal tique de la hotte Rating plate of the cookerhood Typenschild im Inneren der Dunstesse Etichetta all interno della c...

Page 34: ...A20 Beleuchtung Lighting Eclairage Luci Luz Verlichting LEDS 2 x 7 W Fig 9 Fig 10 1 2 1 1 2 2...

Page 35: ...A21 LEDS 2 x 7 W...

Page 36: ...25 Rue des Rosiers Sainte C cile B P 60056 50800 VILLEDIEU LES PO LES France T l 02 33 91 26 50 Fax 02 33 51 54 79 e mail com france roblin fr For outside France Tel 33 0 2 33 91 26 57 Fax 33 0 2 33 5...