7
GB
markings identifying the terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter
E
or by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter
N
or
coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter
L
or
coloured red.
ATTENTION: Do not forget to use adequate plugs to the support brackets. Enquire after the manu
-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs.
GB
1) Draw a vertical line onto the wall from the centre of the cooking appliance up to the ceilling, using a
spirit level and a marker pen as illustrated in
Fig. 1 - item 1
. This is to ensure the correct alignment
of the chimney hood.
2) Place the brackets
item 2
on the wall about 1 or 2 mm from the ceiling or from the upper limit, aligning
its centre on the vertical line. Mark the two eyelet holes of the bracket onto the wall. Drill the holes
for the fixing bracket using an 8 mm masonry bit. Fix the chimney bracket
item 2
using the 4.5 x 50
mm screws and rawl plugs supplied.
3) Draw a horizontal line through the vertical at
650 + item A
when fitting above an electric hotplate
orat
700 + item A
when fitting above a gas hotplate as illustrated in
Fig. 1
. Mark the hole centres for
the canopy fixing brackets
item 4
at
item B
mm as illustrated in
Fig. 3
. Drill the 4 holes for the fixing
brackets using an 8 mm masonry bit. Fix the wall brackets
item 4
using the 4.5 x 45 mm screws and
rawl plugs supplied.
4) Hook the canopy
item 5
onto the wall brackets
item 4
as illustrated in
Fig. 3
. To ensure the cooker
hood is aligned correctly adjust the screws on the top of the canopy as illustrated in
Fig. 3
. When the
hood is aligned correctly mark the hole centre on the wall for the security fixing screw
item8
, which
is located in the right hand bracket on the top of the canopy. Unhook the canopy from the wall and
drill the hole for the security fixing screw. Hook the canopy onto the wall and fix the No 4,5 x 50mm
headed screw and rawl plug to secure the canopy to the wall.
5) Ducting:
The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker
hood is ducted to the outside, charcoal filters are not required.The ducting used must be 150 mm (6
INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS.476
or DIN 4102-B1. Wherever possible use rigid circular pipe which has a smooth interior, rather than
the expanding concertina type ducting.
Maximum length of ducting run:
- 4 metres with 1 x 90° bend.
- 3 metres with 2 x 90° bends.
- 2 metres with 3 x 90° bends.
The above assumes our 150 mm (6 INS) ducting is being installed. Please note ducting components and
ducting kits are optional accessories and have to be ordered, they are not automatically supplied
with the chimney hood.
IN THE EXTRACTION MODE:
a. Place the anti-backflow flats
item 8
over the round outlet
item 6
and connect the ducting 150mm (6
INS) over the round outlet on top of the canopy and secure the connections with appropriate clamp
-
ing rings or adhesive tape (
Fig. 6
).
b. Remove the grease filters (see paragraph Maintenance)
Fig. 5
being sure that the connector of the
mains cable is correctly inserted in the socket placed on the sides of the fan. Before fitting the chimney
to the canopy make the electrical connection as described in the section titled ELECTRICAL. When
the electrical connection has been made, test the lights and the fan motor.
c. Each chimney stack consists of two sections. Fit the upper sections (
Fig. 1 - item 7a & b
) first
byexpanding the chimneys slightly to allow them to clamp around the bracket item 2 and secure the
Summary of Contents for LIDO DESIGN MURALE
Page 34: ...Composants Components Bauelemente Componenti Componentes Onderdelen 2 R 7 5 8 4 32 6 ...
Page 35: ...33 324 m i n 8 0 6 max 1174 378 90 898 500 278 40 164 5 6 5 0 1 1 3 6 5 0 m i n 150 460 53 ...
Page 36: ...34 ...
Page 39: ...37 2 2 1 C 258 mm 460 35 ...
Page 40: ...38 3 4 A 400 mm B 260 mm ...
Page 41: ...39 4 A ...
Page 42: ...40 7 7b 7a 5 6 7b 7a 8 R ...
Page 43: ...41 Eclairage Lighting Beleuchtung Illumiazione Iluminación Verlichting 12EC004 3 x 11 W ...
Page 46: ......