6 . 0 T r o u b l e s h o o t i n g
If you experience a faulty unit, go through this checklist to be able to resolve the problem yourself.
If the unit has been fully checked corresponding to the above listed procedure and the light output is still
not satisfactory, please contact your supplier.
Warning.
Only a properly trained person should undertake the work of servicing other than the above
mentioned.
Symptom
Cause?
Solution
No light
Is the power ON?
Turn on the power.
Is the supply fuse intact?
Replace the fuse.
Is the power cord properly
connected?
Reinsert the power cord.
Is the lid closed and the screw
turned completely tight (interlock
will be activated)? Tighten the
screw completely
Tighten the screw completely.
Close and secure the lid.
Is the light generator too hot?
Check with the installation
instructions.
Cool off for 10 minutes then try
again.
No light, fan running
Is the lamp blown
Replace lamp with new one.
Light switches ON/OFF
Is the light generator too hot
while operating?
Check with installation
instructions.
Is the fan blocked?
Clear the airways.
Is the fan not running?
Reinsert the fan plug.
Is the fan still not running?
Replace the fan with a new one.
The light output has diminished.
Is the lamp old?
Replace the lamp with a new
one.
Are the filters dirty?
Clean the filters.
Is the fiber harness common end
dirty?
Clean the harness common end.