28
Message
Displayed
Probable Cause/Event
Corrective/User Action
Cross wire
-
The perimeter wire is too close to the edge
-
The lawn slope is too big
-
Robomow does not succeed to turn in place
at the edge and it causes the mower to slip
out of the area.
-
Cutting height too low for the lawn and grass
conditions.
-
Move the wire towards the inner side of
the lawn and do not include area with
slopes that are too big.
-
Fill any holes and pits in the ground.
-
Increase the cutting height
-
The drive motors have been working under a
severe load for too long.
-
There is no need to do anything
Robomow will renew automatically the
operation, as the drive motor will cool
down.
Drive overheat
cooling, wait…
Short-circuit detected in Drive Motors.
Contact your Service Dealer.
Enter code
-
The theft guard system is activated
-
Enter the correct 4-digit code. ‘
Theft
Guard’
can be deactivated under
‘
Settings’
. Contact your service provider
for assistance in a lost code situation.
Failure: xyz
-
Internal failure
-
Press ‘go’ to confirm the message; if
the message is still displayed, remove
the battery fuse for 10 seconds and
retry to operate the mower. If the
message still displayed, contact your
service dealer.
CAUTION
– Remove battery fuse before
lifting the mower
-
The Robomow has driven onto an
obstacle, raising the front end. Remove
or exclude this object from the mowing
area.
-
The Robomow is being used on a slope
too steep for safe mowing. Exclude this
from the mowing area.
-
High grass is preventing the front wheel
from fully riding on the ground. Raise
the cutting height.
Frnt wheel prob
-
The Front Wheel has left the ground for
more than 8 – 10 seconds.
-
The ground contains large holes or
indentions where the front wheel can
drop into when passing across. Fill
these areas with dirt and level off.
High temperature
waiting…
-
Robomow is charged and the ambience
temperature is out of range (above 158ºF /
70ºC);
-
Do not do anything, the charging is
stopped and Robomow is waiting for
temperature to change back to the
allowed range; if temperature stays out
of the range for more than 12 hours, the
message is changed to
‘High temp.
Press GO
’.
Insert fuse
for charging
-
Robomow is connected to charging without a
battery fuse
-
Disconnect Robomow from charging,
insert the battery fuse and reconnect to
charging.
Keep charging
if not used
-
Message is displayed every time the power
supply is disconnected.
-
Displayed when the mower isn’t in operation
and not connected to the charging for a long
time.
-
Press any key to change the display
back.
-
Send the mower back to the Base
Station for charging / connect the power
supply or continue in operation.
Key pressed
-
One of the operating panel buttons is
constantly pressed.
-
Press ‘
GO’
to confirm the message and
to continue in operation. The message
is displayed to inform the user about
the problem, but will not prevent the
operation.