113
FAULT INFORMATION
ENG
8. FAULT INFORMATION
8.1. ALARM MESSAGES
In the event of a breakdown during operation the machine stops automatically and alarm messages appear on the
display.
The table lists the displayed messages, the type of problem, the causes and possible solutions.
Important
For these operations a precise technical expertise or ability is required; therefore, these operations must
be exclusively performed by qualified personnel with certified experience acquired in the specific field of
intervention.
List of alarms
Code
Problem
Cause
Solution
E01
Emergency mushroom-head
button alarm.
Emergency
mushroom-head
button pressed
Reset the button and press the
“Reset” button
E02
Carriage emergency
An obstacle has been detected
along the trajectory during the
spool carriage downstroke.
Remove the obstacle and
press the “Reset” button
E03
Hand pallet truck emergency
An obstacle has been detected
on the pallet loading/unloading
ramp.
Remove the obstacle and
press the “Reset” button
E04
Protection alarm
Intervention of safety barriers or
open door
Remove the obstacle and
press the “Reset” button
E30
Inverter alarm:
1. Table
2. Carriage
3. Stretch
Motor faults
Contact technical support
E60
“Film breakage” alarm
The film has broken or spool is
finished
Insert the film or replace spool.
E61
Blocked table alarm
A fault or an obstacle is
preventing the table from
moving
Solve the fault or remove the
obstacle and
press the “Reset”
button
E83
Error alarm
Communication
Electronic fault
Contact technical support
Summary of Contents for Masterplat FREEZER
Page 2: ...ENG 2 Page left blank intentionally ...
Page 22: ...ENG SAFETY INFORMATION 22 Masterplat PLUS Masterplat PLUS TP3 Masterplat PLUS LP ...
Page 31: ...31 TECHNICAL INFORMATION ENG Masterplat PLUS Masterplat PLUS TP3 Masterplat PLUS LP ...
Page 91: ...91 INFORMATION ABOUT THE USE ENG R Manual cycle See Manual Cycle ECO cycle See Eco Cycle ...